Functional description of PRxx1 series controllers Rev.H.doc
2016-10-28
39/43
separated by comma from remaining 5 digits e.g. 238,08887. As a result the first 3 decimal digits
before comma correspond to card Facility Code.
When Facility Code option is active, controller grants the access to all users with the same Facility
Code. Thanks to this feature controller can be used to grant access to larger number of cardholders
whose cards comply to a given Facility Code.
Also, the group of cards with particular Facility Code can be assigned to specific User Groups, thus
all users with the same Facility Code will have the same access rights. Moreover, special options
can be assigned to Facility (see 2.3.2 User Options).
2.7.7 Option: Disable PIN under duress.
[68][F] – Set the option: Auto-relock mode
Enter [F]=0 to disable the option or [F]=1 to enable blocking of door lock upon detection of door
opening or [F]=2 to enable blocking of door lock upon detection of door closing. Default value:
<F=0>. See also 2.7.5 Option: Auto-relock mode.
[69][NF][F] – Program the authorization for User Commands
[NF] parameter specifies particular User Command in range of 10-39. Enter [F]=0 to disable
necessity for authorization
<AUTH>
of particular User Command or [F]=1 to enable necessity for
authorization
<AUTH>
of particular User Command. Default value for all User Commands: <F=1>.
[69][*][0] - Disable necessity for authorization of all User Commands
The command disables the necessity for authorization
<AUTH>
of all User Commands.
[69][*][1] - Enable necessity for authorization of all User Commands
The command enables the necessity for authorization
<AUTH>
of all User Commands.
Note: By default, all User Commands require authorization by means of MASTER or other
authorized identifier.
[70][X] – Set the option: Enable Door Alarm signaling on internal buzzer
Enter [X]=0 to disable the option or enter [X]=1 to enable the option. Default value: <X=0>. See
also 2.7.11 Option: Enable Door Alarm signaling on internal buzzer
[71][FF][A] – Program the F1 Function Key at ID0 Terminal
[FF] parameter specifies function of the key in range of 00..83. See 2.10 Function Keys for the list
of available functions. Enter [A]=0 to disable necessity for authorization of F1 key or enter [F]=1 to
enable necessity for authorization of F1 key at ID0 Terminal. Default value:<F=1>.
[72][FF][A] – Program the F2 Function Key at ID0 Terminal
See command [71]. Default value: <F=1>.
[73][FF][A] – Program the F1 Function Key at ID1 Terminal
See command [71]. Default value: <F=1>.
[74][FF][A] – Program the F2 Function Key at ID1 Terminal
See command [71]. Default value: <F=1>.
[75][new MASTER card] – Program the new MASTER card
The old MASTER card is deleted and new one is recorded.
[76][new MASTER PIN][#] – Program the new MASTER PIN
The old MASTER PIN is deleted and new one is recorded.