Functional description of PRxx1 series controllers Rev.H.doc
2016-10-28
25/43
[01]
Door contact
The input is dedicated to connection of door contact and
monitoring of door opening. If the line is triggered then
controller detects that door is opened, otherwise the door is
closed
[02]
Exit button
When the input line is triggered then controller activates door
lock and grants normal access. This input line can be
connected to exit button
[03]
Disarmed mode
(toggle)
When the input line is activated then controller is switched to
Disarmed Mode and when not activated then controller
remains in Armed Mode. Only one such input can be defined
in controller. If the input line is selected then other methods
for arming/disarming are disabled
[04]
AUX
This input line is used only for registering its activation
[05]
AC lost
This input line is used for reporting the event and triggering
TROUBLE
flag (see 2.7.9 System Flags)
[06]
Low battery
This input line is used for reporting the event and triggering
TROUBLE
flag (see 2.7.9 System Flags)
[07]
Door bell
When the input line is active then bell sound is emitted by
internal buzzer and optionally output line
[15] Door bell
is activated
[08]
Tamper
Activation at this input line is interpreted as sabotage and
TAMPER
flag is triggered (see 2.7.9 System Flags)
[09]
Intruder
Activation at this input line is interpreted as signal from alarm
detector and
INTRUDER
flag is triggered (see 2.7.9 System
[11]
Access disabled
When the input line is active then the controller completely
disables the access
[13]
Arming disabled
When the input line is active then the controller cannot be
armed
[14]
Door lock switch
When the input line is active then the controller
unconditionally unlocks door i.e. it activates door lock switch
[15]
Intruder-delayed
When in Armed Mode triggering of this input starts
ENTRY
DELAY
timer. If controller disarming does not occur within
elapsed time then
INTRUDER
flag is activated
[60]
APB Register reset
When the input line is activated then APB Register Reset
occurs (see 2.7.15 Anti-passback Zones (APB Zones)) and all
users are assigned Not Logged status (see Table 8)
[61]
Arm/Disarm switch
(momentary)
The input line is used for switching between Armed and
Disarmed Modes (see 2.6 Armed and Disarmed Modes)
[64]
Normal door mode
The input line is used for switching the controller into Normal
Door Mode (see 2.5 Door Modes)
[65]
Unlocked door mode
The input line is used for switching the controller into
Unlocked Door Mode (see 2.5 Door Modes)
[66]
Cond. Unlocked door
mode
The input line is used for switching the controller into Cond.
Unlocked Door Mode (see 2.5 Door Modes)
[67]
Locked door mode
The input line is used for switching the controller into Locked
Door Mode (see 2.5 Door Modes).