Specifications
Number of Outputs
Points Per Common
Voltage Category
Operating Voltage Range
Backplane Current (mA) at 5V
Backplane Current (mA) at 24V
Voltage Drop, On-State Output, Max.
Load Current, Min.
Leakage Current, Off-State Output, Max
Signal On Delay, Max (resistive load)
Signal Off Delay, Max (resistive load)
Continuous Current per Module
Continuous Current per Point
Surge Current per Point for 10 ms
Sinking DC Output Modules
1746-OG16
1746-OV8
1746-OV16
1746-OV32
1746-OVP16
16
8
16
32
16
16
8
16
16
16
5V dc
24V dc
4.5…5.5V dc
✶
10…50V dc
5…50V dc
20.4…26.4V dc
180 mA
135 mA
270 mA
190 mA
250 mA
0 mA
0 mA
0 mA
0 mA
0 mA
—
1.2V @ 1.0 A
1.2V @ 0.5 A
1.2V @ 0.5 A
1.0 V @ 1.0 A
0.15 mA
1 mA
1 mA
1 mA
1 mA
0.1 mA
1 mA
♣
1 mA
♣
1 mA
1 mA
♣
0.25 ms
0.1 ms
0.1 ms
0.1 ms
0.1 ms‡
0.50 ms
1.0 ms
1.0 ms
1.0 ms
1.0 ms
N/A
8.0 A @30 °C (86 °F)
4.0 A @60 °C (140 °F)
8.0 A @0…60 °C
(32…140 °F)
6.4 A @0…60 °C
(32…140 °F)
24 mA
1.0 A @30 °C (86 °F)
0.5 A @60 °C (140 °F)§
0.50 A @30 °C (86 °F)
0.25 A @60 °C (140 °F)§
0.50 A @ 30 °C
0.25 A @ 60 °C
1.5 A @30 °C (86 °F)
1.0 A @60 °C (140 °F)
➤
N/A
3.0 A
1.0 A @30 °C (86 °F)
1.0 A @60 °C (140 °F)
4.0 A
✶
50 mV peak to peak ripple (max).
The 1746-OVP16 module features a fused common and blown fuse LED indicator.
‡ Fast turn-off modules provide fast OFF delay for inductive loads. Fast turn-off delay for inductive loads is accomplished with surge suppressors on this module. A suppressor at the load is not
needed unless another contact is connected in series. If this is the case, a 1N4004 diode should be reverse wired across the load. This defeats the fast turn-off feature. Comparative OFF delay
times for 1746-OB8, 1746-OV8 and fast turn-off modules, when switching Bulletin 100-B110 (24 W sealed) contactor, are: 1746-OB8 and 1746-OV8 modules OFF delay = 152 ms; fast turn-
off modules OFF delay = 47 ms.
§ Recommended surge suppression: For transistor outputs, when switching 24V dc inductive loads, use a 1N4004 diode reverse-wired across the load. Refer to the SLC 500 Modular Hardware
Style User Manual, publication 1747-UM011, for more information on surge suppression.
♣
To limit the effects of leakage current through solid-state outputs, a loading resistor can be connected in parallel with your load. For transistor outputs, 24V dc operation, use a 5.6 K
Ω
, 1/2 W
resistor.
➤
Fast off-delay for inductive loads is accomplished with surge suppressors on the 1746-IB6EI and 1746-OBP8 series B and later, 1746-OB16E series B and later, 1746-OBP16 and 1746-
OVP16 modules. A suppressor at the load is not needed unless another contact is connected in series. If this is the case, a 1N4004 diode should be reverse-wired across the load. This defeats
the fast turn-off feature.
Repeatability is once every 1 s @ 30 °C (86 °F). Repeatability is once every 2 s @ 60 °C (140 °F).
Surge current = 32 A per module for 10 ms.
Specifications
Number of Outputs
Points Per Common
Voltage Category
Operating Voltage Range
Backplane Current (mA) at 5V
Backplane Current (mA) at 24V
Voltage Drop, On-State Output, Max.
Load Current, Min.
Leakage Current, Off-State Output, Max
Signal On Delay, Max (resistive load)
Signal Off Delay, Max (resistive load)
Continuous Current per Module
Continuous Current per Point
Surge Current per Point for 10 ms
➤
Sourcing DC Output Modules
1746-OB6EI
1746-OB8
1746-OB16
1746-OB16E
1746-OB32 1746-OB32E
1746-OBP8
♣
1746-OBP16
6 Electronically
Protected
8
16
16 Electronically
Protected
32
32 Electronically
Protected
8
16
Individually
Isolated
8
16
16
16
16
4
16
24V dc
10 …30V dc
10…50V dc
10…30V dc
5…50V dc 10…30V dc
20.4…26.4V dc
46 mA
135 mA
280 mA
135 mA
190 mA
135 mA
250 mA
0 mA
0 mA
0 mA
0 mA
0 mA
0 mA
0 mA
0 mA
1.0V @ 2.0 A
1.2V @ 1.0 A
1.2V @ 0.5 A
1.0V @ 0.5 A
1.2V @ 0.5 A
1.0V @ 2.0 A
1.0V @ 1.0 A
1 mA
1 mA
1 mA
1 mA
1 mA
1 mA
1 mA
1 mA
1 mA§
1 mA§
1 mA§
1 mA§
1 mA
1 mA
1 mA§
1 mA§
1.0 ms
✶
0.1 ms
0.1 ms
1.0 ms
✶
0.1 ms
1.0 ms
1.0 ms
✶
0.1 ms
✶
2.0 ms
1.0 ms
1.0 ms
1.0 ms
1.0 ms
2.0 ms
2.0 ms
1.0 ms
12.0 A @ 0…60
°C (32 °…140 °F)
8.0 A @ 30 °C (86 °F)
4.0 A @ 60 °C (140 °F)
8.0 A @ 0…60 °C (32…140 °F)
6.4 A @ 0…60 °C
(32…140 °F)
2.0 A @ 0…60 °C
(32 °…140 °F)‡
1.0 A @ 30 °C (86 °F)
0.50 A @ 60 °C (140 °F)
0.50 A @ 30 °C (86 °F)
0.25 A @ 60 °C (140 °F)
1.0 A @ 30 °C (86 °F)
0.50 A @ 60 °C (140 °F)‡
0.50 A @ 30 °C (86 °F)
0.25 A @ 60 °C (140 °F)
2.0 A @ 0…60 °C
(32…140 °F)‡
1.5 A @ 30 °C (86 °F)
1.0 A @ 60 °C (140 °F)‡
4.0 A
3.0 A
2.0 A
1.0 A @ 30 °C (86 °F)
1.0 A @ 60 °C (140 °F)
4.0 A
✶
Fast turn-off modules provide fast OFF delay for inductive loads. Comparative OFF delay times for 1746-OB8, 1746-OV8 and fast turn-off modules, when switching Bulletin 100-B110 (24 W sealed)
contractor, are: 1746-OB8 and 1746-OV8 modules OFF delay = 152 ms; fast turn-off modules OFF delay = 47 ms.
The 1746-OBP16 module features a fused common and blown fuse LED indicator.
‡ Fast off-delay for inductive loads is accomplished with surge suppressors on the 1746-IB6EI, 1746-OBP8 series B and later, 1746-OB16E series B and later, 1746-OBP16, and 1746-OVP16 modules. A
suppressor at the load is not needed unless another contact is connected in series. If this is the case, a 1N4004 diode should be reverse-wired across the load. This defeats the fast turn-off feature.
§ To limit the effects of leakage current through solid-state outputs, a loading resistor can be connected in parallel with your load. For transistor outputs, 24V dc operation, use a 5.0 K
Ω
, 1/2 W resistor on
1746-OB8, 1746-OB16, and 1746-OB16E modules and a 5.6 K
Ω
, 1/2 W resistor on 1746-OB6EI, 1746-OBP8, 1746-OBP16 modules.
♣
An external fuse can be used to protect this module from short circuits. Recommended fuse is SANO MQ 4-3.15 A, 5x20 mm.
➤
Repeatability is once every 1 s @ 30 °C (86 °F). Repeatability is once every 2 s @ 60 °C (140 °F).