background image

10

Rockwell Automation Publication 2198-IN001D-EN-P - February 2016

Kinetix 5500 Servo Drives

Attach the Motor Cable Shield Clamp

A shield clamp and two screws are supplied with each Kinetix 5500 drive. Use the clamp to bond the motor cable shield-braid to chassis ground.

Kinetix VP Servo Motors

These examples illustrate 2090-CS

x

M1DF/DG motor cables with connections to Kinetix VP motors and using 2198-KITCON-DSL feedback 

connector kits. If your motor connections are coming from other compatible Allen-Bradley® servo motors/actuators, see 

Other Allen-Bradley 

Motors and Actuators

 on 

page 11

.

Cable Shield Clamp Installation

IMPORTANT

• Loosen the retention screw, if needed, until you can start threading both clamp screws with the cable shield under the clamp.
• Make sure the cable clamp tightens around the cable shield and provides a good bond between the cable shield and the drive chassis.

Motor Cable

Shield Clamp

2198-KITCON-DSL

Motor Feedback

Connector Kit

Motor Power
(MP) Connector

Motor Brake
(BC) Connector

Exposed shield braid 
under clamp.

Feedback cable routed

around the shield clamp.

Shield Clamp Screws (2)
2.0 N•m (17.7 lb•in), max

Kinetix 5500 Servo Drives,

Frame 1 or 2, Front View

(frame 1 is shown)

2090-CSBM1DF-18AA

xx

Single Motor Cable

Clamp features apply 

to all frame sizes.

Servo Drive

Shield Clamp

Retention Screw

Motor Cable

Shield Clamp

Motor Power
(MP) Connector

Motor Brake
(BC) Connector

Exposed shield braid 
under clamp.

Shield Clamp Screws (2)

Feedback cable routed

within the shield braid.

2198-KITCON-DSL

Motor Feedback

Connector Kit

Kinetix 5500 Servo Drives,

Frame 2 or 3, Front View

(frame 2 is shown)

2090-CSBM1DF-14AA

xx

Single Motor Cable

Servo Drive

Retention Screw

(loosen, do not remove)

IMPORTANT

When the drive/motor combination calls for 18 AWG cable, the feedback cable routes 
around the motor cable shield clamp.

IMPORTANT

When the drive/motor combination calls for 14 or 10 AWG cable, the feedback cable 
routes along with the power and brake wiring.

Summary of Contents for Allen-Bradley 2198-H***-ERS Series

Page 1: ...80 and GuardLogix 5570 or CompactLogix 5370 and Compact GuardLogix 5370 controllers Topic Page Summary of Changes 1 About the Kinetix 5500 Drives 1 Catalog Number Explanation 2 Before You Begin 2 Remo...

Page 2: ...r impedance grounded power configurations Removing the screws involves gaining access opening the side door and removing the screws Removing the grounding screws in multi axis configurations is best d...

Page 3: ...mpliance Reduced electrical noise Most stable operation Reduced voltage stress on components and motor bearings AC fed ungrounded Corner grounded Impedance grounded Both screws removed Helps avoid sev...

Page 4: ...n Refer to the Kinetix Servo Drives Technical Data publication GMC TD003 for Kinetix 5500 drive dimensions In multi axis shared bus configurations drives must be spaced by aligning the zero stack tab...

Page 5: ...at No Frame A mm in B mm in C mm in D mm in E mm in Drill Hole Patterns F mm in G mm in 2198 H003 ERSx 1 50 1 97 170 6 69 200 7 87 226 8 90 215 8 46 193 68 7 62 4 51 0 18 2198 H008 ERSx 2198 H015 ERSx...

Page 6: ...13 Link Activity status indicators 20 24V control input power CP connector 7 Zero stack mounting tab cutout 14 Motor power MP connector 21 Safe torque off STO connector 3 applies to only 2198 Hxxx ERS...

Page 7: ...2 DC DC Pin Description Signal 1 DC bus connections DC 2 DC CP Pin Description Signal 1 24V power supply customer supplied 24V 2 24V common 24V MP Pin Description Signal Color U Three phase motorpowe...

Page 8: ...put 1 This is a dual function input IN1 1 1 This signal has dual functionality You can use IN1 IOD 1 as registration or Home input 2 I O common for customer supplied 24V supply COM 3 24V current sinki...

Page 9: ...icalData publication KNX TD004 for cable specifications 8 0 0 31 0 5 0 6 4 4 5 3 2198 H070 ERSx 2 5 6 4 14 10 10 0 0 39 0 5 0 8 4 4 7 1 2198 Hxxx ERSx PELV SELV 24V power single axis CP connector CP 1...

Page 10: ...is Motor Cable Shield Clamp 2198 KITCON DSL Motor Feedback Connector Kit Motor Power MP Connector Motor Brake BC Connector Exposed shield braid under clamp Feedback cable routed around the shield clam...

Page 11: ...attaching the motor power brake shield clamp IMPORTANT If the power brake cableshield has a loose fit inside the shield clamp insert theclamp spacer between the shield clamp and the drive to reduce t...

Page 12: ...ications Drive Cat No Drive Voltage nom Phase Bussmann Fuses Cat No Molded Case CB Cat No DIN gG Fuses Amps max Molded Case CB Cat No 2198 H003 ERSx 240V Single phase KTK R 2 140U D6D2 B10 2 140U D6D2...

Page 13: ...SP 140G G6C3 C40 35 140G G6C3 C40 Kinetix 5500 Drive Cat No Drive Voltage three phase nom Bussmann Fuses Cat No Molded Case CB Cat No 2 Axes 3 Axes 4 Axes 5 Axes 2 Axes 3 Axes 4 Axes 5 Axes 2198 H003...

Page 14: ...meets the following UL requirements for solid state overload protection Refer to your servo drive user manual for the interconnect diagram that illustrates the wiring between your motor and drive Kin...

Page 15: ...hnical Data publication KNX TD004 Provides product specifications for Bulletin 2090 motor and interface cables low profile connector kits drive power components and other servo drive accessory items K...

Page 16: ...your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at http literature rockwellautomation com idc groups literature documents...

Reviews: