58
IFP and Damper Body Service
Clamp the damper body in the vise.
Clamp the damper body in the vise.
Install the IFP into the damper body, tabbed side inside the damper
Install the IFP into the damper body, tabbed side inside the damper
first, indented side out.
first, indented side out.
Insert the Deluxe IFP Height Tool into the damper body, flat on top of
Insert the Deluxe IFP Height Tool into the damper body, flat on top of
the IFP.
the IFP.
Slowly and carefully push the IFP to the depth for the shock stroke (A)
Slowly and carefully push the IFP to the depth for the shock stroke (A)
printed on the damper body, as specified in the table below.
printed on the damper body, as specified in the table below.
Do not push the IFP in too far. If it is pushed into the damper body
Do not push the IFP in too far. If it is pushed into the damper body
beyond the specified depth, the IFP must be removed and reinstalled.
beyond the specified depth, the IFP must be removed and reinstalled.
Eye-to-Eye Length
(mm)
Shock Stroke
(mm)
IFP Insertion
Depth (mm)
170 (Standard or Bearing Eyelet)
145 (Trunnion Eyelet)
27.5 - 35
49.5
190 (Standard or Bearing Eyelet)
165 (Trunnion Eyelet)
37.5 - 45
58
210 (Standard or Bearing Eyelet)
185 (Trunnion Eyelet)
47.5 - 55
66.5
230 (Standard or Bearing Eyelet)
205 (Trunnion Eyelet)
57.5 - 75
75
Tighten the air valve core in the damper body.
Tighten the air valve core in the damper body.
A
5
Deluxe IFP Height Tool
Deluxe IFP Height Tool
IFP depth
6
Schrader valve tool