2.3 Referenced Documents
The following documents are referenced throughout the procedure. Check
http://www.planetarysystemscorp.com
to ensure the latest revision.
Table 2-2: Referenced documents
Document
Necessary For
2000785 MkII MLB User Manual
Adjoining structure flatness, Lightband circularity, LCT qty., detailed
Lightband description
3000224 MLB Training Record
Verify approval to operate Lightband(s)
1001015 MLB Warranty
-
3000272 Upper Ring Stop Procedure
If using Stow or Deploy Upper Ring Stops to restrain Lightband
2001025 Separation Connector Data Sheet Attaching Separation Connectors
2002204 Separation Switch Data Sheet
Attaching Separation Switches
2.4 Required Equipment
The items listed below are proven to properly operate the Lightband as presented in this procedure. PSC strongly
recommends using this equipment. All procedure steps listing recommended settings assume the PSC Typically
Used equipment. All equipment substitutions shall be thoroughly vetted prior to use with the Lightband. For
instance, some customers create a custom data acquisition system, thereby negating the need for an
oscilloscope. Further, all electrical paths and Lightband switch states shall be considered. See section 16.
Table 2-3: Mechanical attachment (section 6)
Qty
Item
Make & Model Typically Used by PSC
1
Adjoining structure for Upper Ring
PSC 2000741 Transition Ring
1
Adjoining structure for Lower Ring
PSC 2000741 Transition Ring
AR
0.25 inch SHC fastener (to attach Lower and Upper Rings to
adjoining structure)
NAS1351N4-XX or PSC
4000845
Reduced Head SHC Screw
AR
<0.50 inch OD washer (to attach Lower and Upper Rings to
adjoining structure)
NAS620C416
AR
0.25 inch nut (if applicable, to attach Lower and Upper Rings to
adjoining structure)
NASM21043-4
1
3/16 inch hex key (minimum 1.5 inch shank length) with interface
for torque wrench
-
1
Torque wrench
, 150 in∙lb capability
Sturtevant Richmont CCM-150I
1
Small tweezers to aide in fastener handling
-
AR
Isopropanol (to clean adjoining structure and Lightband
interfacing surfaces)
-
AR
Lint Free Wipes (to clean adjoining structure and Lightband
interfacing surfaces)
-
AR
Ability to measure flatness of adjoining structures (granite table
and thickness gages, CMM, laser, etc.)
Starrett 66 Thickness Gage and granite
table
AR
Ability to maintain and measure circularity of Lower and Upper
Rings after attachment (custom flat head screws or gage pins
along with known precise adjoining structure, caliper that spans
MLB, etc.)
PSC 2002753 FLH Alignment Screw
and 2000741 Transition Ring