![ROCKET LAB PSC MOTORIZED Lightband MKII Operating Procedure Download Page 34](http://html1.mh-extra.com/html/rocket-lab/psc-motorized-lightband-mkii/psc-motorized-lightband-mkii_operating-procedure_1472596034.webp)
Copyright PSC
2000781K MkII MLB Operating Procedure
Page 34 of 68
Table 8-1: Stow electrical verification (values apply at NTP)
Stow Electrical Parameters
MLB Size
Item
Description (1)
Units
Allowable
Measured
Min
Max
Motor
A
Motor
B
8.000-12
1
First peak current
A/mtr
1.9
3.0
2
Second peak current
A/mtr
0.4
1.4
3
Motors powered duration
s
0.5
1.1
11.732-18
1
First peak current
A/mtr
1.9
3.0
2
Second peak current
A/mtr
0.7
1.6
3
Motors powered duration
s
0.5
1.1
13.000-20
1
First peak current
A/mtr
1.9
3.0
2
Second peak current
A/mtr
0.8
1.7
3
Motors powered duration
s
0.6
1.1
15.000-24
1
First peak current
A/mtr
1.9
3.0
2
Second peak current
A/mtr
0.9
1.8
3
Motors powered duration
s
0.6
1.1
18.250-28
1
First peak current
A/mtr
1.9
3.0
2
Second peak current
A/mtr
1.0
1.9
3
Motors powered duration
s
0.6
1.2
19.848-28
1
First peak current
A/mtr
1.9
3.0
2
Second peak current
A/mtr
1.0
1.9
3
Motors powered duration
s
0.6
1.2
23.250-32
1
First peak current
A/mtr
1.9
3.0
2
Second peak current
A/mtr
1.1
2.1
3
Motors powered duration
s
0.65
1.3
24.000-36
1
First peak current
A/mtr
1.9
3.0
2
Second peak current
A/mtr
1.1
2.1
3
Motors powered duration
s
0.65
1.3
31.600-48
1
First peak current
A/mtr
2.1
3.2
2
Second peak current
A/mtr
1.4
2.3
3
Motors powered duration
s
0.65
1.3
38.810-60
1
First peak current
A/mtr
2.1
3.2
2
Second peak current
A/mtr
1.5
2.3
3
Motors powered duration
s
0.65
1.3
(1) Use the current channels to determine
Motors powered duration.