1 Features and technical data
6
In the event of failure
Operations on internal components and repairs may
exclusively be carried out by a TAC, only using original
parts.
▶
In the event of failure of the appliance and/or break-
age of any component, do not attempt to repair and/
or restore and immediately contact the TAC.
Routine maintenance
Proper maintenance assures the efficiency and good
operation of the appliance over time.
▶
Maintenance must be performed according to the
manufacturer's instructions (see Chapter 7 p. 35)
and in compliance with current regulations.
▶
Appliance maintenance and repairs may only be en-
trusted to firms legally authorised to work on gas ap-
pliances and systems.
▶
Enter into a maintenance contract with an author-
ised specialised firm for routine maintenance and for
servicing in case of need.
▶
Only use original parts.
Decommissioning and disposal
If the appliance is to be disposed of, contact the manu-
facturer for its disposal.
Keep the Manual
This "Installation, Use and Maintenance Manual" must
always accompany the appliance and must be handed
to the new owner or installer in the event of sale or
removal.
III�2 CONFORMITY
EU Directives and standards
The absorption heat pumps of the GAHP series are certified as
conforming to standard EN 12309-1 and -2 and comply with the
essential requirements of the following Directives:
▶
2009/142/EC "Gas Appliances Directive" as amended and
added.
▶
2004/108/EC "Electromagnetic Compatibility Directive" as
amended and added.
▶
2006/95/EC "Low Voltage Directive" as amended and added.
▶
2006/42/EC "Machine Directive" as amended and added.
▶
97/23/EEC "Pressure Equipment Directive" as amended and
added.
Furthermore, they comply with the requirements of the follow-
ing standards:
▶
UNI EN 677 Specific requirements for condensing boilers
with nominal heating capacity up to 70 kW.
▶
EN 378 Refrigerating systems and heat pumps.
Other applicable provisions and standards
The design, installation, operation and maintenance of the sys-
tems shall be carried out in compliance with current applicable
regulations, depending on the Country and location, and in
accordance with the manufacturer's instructions. In particular,
regulations regarding the following shall be complied with:
▶
Gas systems and equipment.
▶
Electrical systems and equipment.
▶
Heating and air conditioning systems, and heat pumps.
▶
Environmental protection and combustion products ex-
haust.
▶
Fire safety and prevention.
▶
Any other applicable law, standard and regulation.
III�3 EXCLUSIONS OF LIABILITY AND
WARRANTY
Any contractual or extra-contractual liability of the
manufacturer for any damage caused by incorrect in-
stallation and/or improper use and/or failure to comply
with regulations and with the manufacturer's direc-
tions/instructions shall be disclaimed.
In particular, the warranty on the appliance may be ren-
dered void by the following conditions:
▶
Incorrect installation.
▶
Misuse.
▶
Failure to comply with the manufacturer's indica-
tions on installation, use and maintenance.
▶
Alteration or modification of the product or any part
thereof.
▶
Extreme operational conditions or however out-
side of the operational ranges set forth by the
manufacturer.
▶
Damages caused by external agents such as salts,
chlorine, sulphur or other chemical substances con-
tained in the installation water or present in the air of
the installation site.
▶
Abnormal actions transmitted by the plant or instal-
lation to the appliance (mechanical stresses, pres-
sure, vibrations, thermal dilations, power surges...).
▶
Accidental damages or due to force majeure.
1 FEATURES AND TECHNICAL DATA
1�1 FEATURES
Operation
Based on the thermodynamic water-ammonia absorption cycle
(H
2
0–NH
3
), the appliance produces hot water using outdoor air
as a renewable energy source (cold source) and natural gas (or
LPG) as primary energy.
The thermodynamic cycle takes place within a hermetically
sealed circuit, in welded construction, perfectly tight, factory-
tested, which does not require any maintenance or coolant
top-ups.
Mechanical and thermo-hydraulic components
▶
steel sealed circuit, externally treated with epoxy paint;