Appendices
Installation, Use and Maintenance Manual – GAHP-A
41
Figure 3
Bivalent temperature
T
biv
TOL <
T
designh
°C
For air-to-water heat pumps:
Operation limit temperature
TOL
-22
°C
Heating water operating limit
WTOL
65
°C
Off mode
P
OFF
0,000
kW
Rated heat output
Psup
-
kW
Thermostat-off mode
P
TO
0,021
kW
Type of energy input
Standby mode
P
SB
0,005
kW
Crankcase heater mode
P
CK
-
kW
Other items
Capacity control
For air-to-water heat pumps:
Rated air flow rate, outdoors
__
10000
m³/h
Sound power level, indoors/
outdoors
L
WA
- / 80
dB
For water- or brine-to-water
heat pumps: Rated brine or
water flow rate, outdoor heat
exchanger
__
-
m³/h
Additional information required by COMMISSION REGULATION (EU) No 813/2013, Table 2:
Emissions of nitrogen oxides:
NO
x
40
mg/
kWh
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for
heating Pdesignh , and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating
sup(Tj) .
Power consumption in modes other than active mode
Supplementary heater
variable
monovalent