RX-64
44
4. Appendix
Range
Each data has valid range. When the Write commancd that is off the valid range is
transmitted, an error is returned. The below table shows the length and range of data
that the user can write. 16bit Data is displayed in two bytes, L and H. These two bytes
should be written as one Instruction Packet at once.
Write
Address
Writing Item
Length
(bytes)
Min
Max
3(0X03)
ID
1
0
253(0xfd)
4(0X04)
Baud Rate
1
0
254(0xfe)
5(0X05)
Return Delay Time
1
0
254(0xfe)
6(0X06)
CW Angle Limit
2
0
1023(0x3ff)
8(0X08)
CCW Angle Limit
2
0
1023(0x3ff)
11(0X0B)
the Highest Limit Temperature
1
10(0x10)
99(0x63)
12(0X0C)
the Lowest Limit Voltage
1
50(0x32)
250(0xfa)
13(0X0D)
the Highest Limit Voltage
1
50(0x32)
250(0xfa)
14(0X0E)
Max Torque
2
0
1023(0x3ff)
16(0X10)
Status Return Level
1
0
2
17(0X11)
Alarm LED
1
0
127(0x7f)
18(0X12)
Alarm Shutdown
1
0
127(0x7f)
19(0X13)
(Reserved)
1
0
1
24(0X18)
Torque Enable
1
0
1
25(0X19)
LED
1
0
1
26(0X1A)
CW Compliance Margin
1
0
254(0xfe)
27(0X1B)
CCW Compliance Margin
1
0
254(0xfe)
28(0X1C)
CW Compliance Slope
1
1
254(0xfe)
29(0X1D)
CCW Compliance Slope
1
1
254(0xfe)
30(0X1E)
Goal Position
2
0
1023(0x3ff)
32(0X20)
Moving Speed
2
0
1023(0x3ff)
34(0X22)
Torque Limit
2
0
1023(0x3ff)
44(0X2C)
Registered Instruction
1
0
1
47(0X2F)
Lock
1
0
1
48(0X30)
Punch
2
0
1023(0x3ff)
[Control Table Data Range and Length for Writing]