RX-64
3-5-3
REG WRITE
Function
The REG_WRITE command is similar to the WRITE_DATA command in terms of
function, but differs in terms of the timing that a command is executed. When Instruction
Packet arrives, it is saved in Buffer and the Write operation remains in the standby state.
At this moment, Registered Instruction (Address 44 (0x2C)) is set as “1”. Then, when
Action Instruction Packet arrives, Registered Instruction changes into “‘0” and the
registered Write command is finally executed.
Length
N+3 (if the number of Writing Data is N)
Instruction
0X04
Parameter1
Start Address to write Data
Parameter2
First data to write
Parameter N+1
Nth data to write
3-5-4
ACTION
Function
This command is to execute the Write action registered by REG_WRITE
Length
0X02
Instruction
0X05
Parameter
NONE
The Action command is useful when several RX-64s are moved with accuracy at the
same time. When several running gears are controlled via communication, there is a
little time difference in terms of enabling time between the first and the last running gear
getting commands. RX-64 has resolved this problem by using Action Instruction.
Note
In case of transmiting the Action command to more than two RX-64s,
Broadcast ID(0XFE) should be used, but Status Packet is not returned at
this time.