3
3.0 TECHNICAL DATA
The ATHENA R.S. is a room sealed, inset live fuel effect gas heater with coals.
The heater can be mounted only on a non-combustible hearth, and can be fitted into a suitable fire surround. The heater
can be installed on a normal brick wall from the inside of a building making it ideal for rooms where access from the
outside is difficult, for example multi-storey buildings. If the heater is to be installed on a combustible wall, then the
combustible wall kit,
ÿ
Part No. 994530, must be used together with a 152 mm rebated surround.
Four flues are available:
ÿ
Part No.
Mini (telescopic)flue for walls from 280mm to 353mm
990177
Short (requires cutting)flue for walls from 225mm to 353mm
993241
Medium (telescopic) flue for walls from 353mm to 507mm
993240
Long (telescopic) flue for walls from 507mm to 658mm
993239
The heater is not supplied with the a flue. The flue is supplied separately.
The heater is for use on Natural Gas only (G20 at 20 mbar supply pressure).
The appliance data badge is positioned on the left hand side of the backplate.
The following optional extras are available: -
ÿ
Part No.
Combustible Wall Kit
994530
Terminal Guard
994371
Gas Safety (Installation and Use) Regulations 1994 (as amended). It is the law that all gas appliances are installed by
competent persons in accordance with technical requirements.
The following items relate to this appliance:
1. BS 5871
2. BS 5440
3. BS 6891
4. The Building Regulations issued by the Department of Environment and the Building Standards (Scotland)
(Consolidation) Regulations issued by the Scottish Development Department.
5. Any other relevant British Standard Code of Practice and/or Local Building Regulations.
6. These installation instructions and in accordance with the rules in force.
1.0 DESCRIPTION
2.0 INSTALLATION REQUIREMENTS
DIMENSIONS
Height
690 mm
Width
645 mm
Depth
125 mm
Weight
29.2 Kg
Gas Type
Natural Gas
Max. Heat Input
4.5 kW
Max. Heat Output
3.53 kW
Height to Centre Line of Flue
351mm
Setting Pressure
COLD 17.5 mbar ± 1.0 mbar
Min Supply Pressure
20 mbar
Burner - Main
Bray Aerated Duplex
- Pilot
SIT 0150060
Injector - Upper
Bray Cat 77/180
- Lower
Bray Cat 77/160
- Pilot
SIT No. 34
Ignition
Battery Operated Electronic Ignition. Battery Size 9V MN1604 or 6LR61
Slider Control / FSD
Concentric TESA 2875-002
Spark Gap
3 to 4 mm
Control Knob Settings
OFF, FULL, HIGH, ECON, MED, PILOT