11
Fig 8.
TOP
Fixing screw positions
Fixing screw positions
Rear coal supports
(h) Insert the heater into the opening, ensuring that the flue is inserted into the hole in the outer section of the wall. Push
the heater back against the wall and pull each fixing cable taut. Thread the cable adaptors onto the cables and slide up
to the tensioning bolts. While keeping the fixing cables taut, tighten the grub screw in the cable adaptors so that it grips
the fixing cable. (see Fig 4.)
(i) Using a spanner, unscrew each tensioning bolt by approximately 20 mm to tension the cable. Prevent the cable
adaptors from rotating while unscrewing the tensioning bolts.
(j) Re-fit the lower air guide ensuring that the long edge with the flange points down and rests on top of the first
heat exchanger.
(g) If a terminal guard is required (optional extra
ÿ
No. 994731) fit it with the kit supplied ensuring that it is positioned as
shown in Fig 7.
10.3
Install Fuel Effect
(See Fig 8.)
Remove the coal pack from the heater and remove the coal effect from its pack. The coal effect is a one piece assembly
and has a ‘tunnel’ cut out at one end. Fit the coal effect so that this tunnel is over the pilot burner on the right side of the
firebox. The coal effect should come to rest on the full length inner front support and also on the two rear coal supports.
10.4
Replace Glass Door
Refit the glass door ensuring all studs protrude through the door evenly. Replace the wingnuts and tighten evenly.
Fig 7.