14.11
Removing The Pilot Burner
(a) Remove the controls assembly as previously described in Section 14.2.
(b) Remove the four screws securing the pilot burner to the combustion
chamber.
(c) Remove the pilot burner.
(d) Refitting is the reverse procedure of removal.
(e) After refitting the pilot burner, visually check that the pilot flames are as
shown in Fig 22.
14.12
Removing The Ignition Unit
(a) Remove the outer case as previously described in Section 14.1.
(b) Disconnect the red and blue wires from the ignition unit.
(c) Remove the two screws securing the unit to its mounting bracket.
Note:
This operation will also remove the ignition unit heat shield.
(d) Refitting is the reverse procedure of removal.
14.13
Removing The Ignition Micro switch
(a) Remove the outer case as previously described in Section 14.1.
(b) Disconnect the red and blue wires from the ignition unit.
(c) Cut the cable tie securing the wires to the gas valve.
(d) Remove the two screws securing the micro switch to the controls assembly and withdraw the switch.
(e) Refitting is the reverse procedure of removal.
14.14
Removing The Thermocouple Break Micro switch
(a) Remove the outer case as previously described in Section 14.1.
(b) Disconnect the yellow wires from the thermocouple break.
(c) Remove the two screws securing the micro switch to the controls assembly and withdraw the switch.
(d) Refitting is the reverse procedure of removal.
ÿ
PART NUMBER
DESCRIPTION
991328
Coal Bed
990274
Control Knob
990284
Control Knob Bezel
822291
Gas Shut Off Tap
822290
Slider Control / FSD
820363
Ignition Electrode
822295
Thermocouple
990197
Glass Door Assembly
993911
Ignition Lead
18
15.0 SPARES AND SERVICE
For spares and service apply to your local supplier or installer stating that the appliance is a ATHENA R.S. The serial number
of the heater is shown on the small label on the lower right side of the heater.
Advantage should be taken of regular servicing/inspection by a CORGI registered service agent to ensure continued safe and
efficient operation of the heater.
16.0 SHORT LIST OF PARTS
All these spares plus a comprehensive list are available by contacting the address below.
990266 Issue 5
ROBINSON WILLEY LIMITED
Mill Lane, Old Swan, Liverpool. L13 4AJ. England.
Telephone: 0151-228-9111 Fax: 0151-228-6661
15mm
13mm
Fig 22.