7
3.2 Changing the lamp
DANGER !
Install the lamp with the fixture unplug from mains !
To insert the new lamp.
1. Disconnect the fixture from mains and allow it to cool at least 20 minutes.
2. .Loosen the two quarter-turn fasteners (1) on a lamp cover and remove the lamp cover (2) to get into lamp
compartment.
3. Remove both Fastons (3) from flat blades of the lamp.
4. Holding the lamp by its ceramic base (4), carefully pull the lamp outwards until you break force of
spring locks (5) keeping the lamp in the lamp compartment.
5 Holding the new lamp by its ceramics base (4), gently insert the lamp into lamp compartment until it snaps
into spring locks (5).
Do not install a lamp with a higher wattage! A lamp like this generates temperatures the device is not de signed
for. Damages caused by non-observance are not subject to warranty. Please follow the lamp manufacturer‘s
notes!
Warning:
do not touch the lamp’s envelope with bare hands. Should this happen, clean the bulb with a cloth
soaked in alcohol and dry it
6. Slide both Fastons (3) onto lamp blades and check this connection
7
. Re-insert the lamp cover (2) and tighten the two quarter-turn fasteners (1) .
8. Connect the fixture to the mains.
9. Reset the "Lamp On Time” and "Lamp Strikes” counters in the menu "Information”.
Never operate this fixture without the lamp!
Do not operate this fixture without the lamp cover!