![RNLI Atlantic 85 Manual Download Page 12](http://html1.mh-extra.com/html/rnli/atlantic-85/atlantic-85_manual_1467597012.webp)
12
Activity 2 - Personal Competencies
B Class Atlantic 85 Manual – First Issue, June 2017
Activity 2 - Personal Competencies
• A crew member should discharge the fire extinguisher
completely into the cowl opening of the running engine
as shown below.
• The engine will stall. Do not remove the engine hood.
Do not restart the engine.
• Assess if the fire is extinguished.
Electrical fire in the console
If an electrical fire occurs in the console, do the following:
• Assess if fire is safe to tackle.
• If safe to do so, turn off the power and isolate by turning
the two yellow handles shown below.
• Fire the extinguisher into the internal space and
close door.
SAR unit firefighting
The Atlantic 85 carries a 0.5kg CO
2
fire extinguisher which
has approximately 2-3 seconds of effective discharge time.
It is located in front of the helm’s starboard foot strap.
Engine fires
If an engine fire should occur, do the following;
• Alert the helm.
• Ensure the vessel is in a safe area.
• Do not stop engine.
• If safe to tackle, use the CO
2
extinguisher.
• The helm will turn the engine towards the sponson.
Emergency Situations
EOP
Summary of Contents for Atlantic 85
Page 1: ...B CLASS ATLANTIC 85 MANUAL...
Page 2: ......
Page 4: ......
Page 8: ......
Page 11: ...Activity 2 Personal Competencies Personal Competencies Activity 2...
Page 31: ...Activity 3 Launch and Recovery Launch and Recovery Activity 3...
Page 37: ...Activity 4 SAR Unit Handling and Seamanship SAR Unit Handling and Seamanship Activity 4...
Page 51: ...Activity 5 Search and Rescue Search and Rescue Activity 5...
Page 57: ...Activity 6 Communications Communications Activity 6...
Page 67: ...Activity 7 Navigation Navigation Activity 7...
Page 70: ......
Page 71: ...Activity 9 Propulsion and Auxiliary Systems Propulsion and Auxiliary Systems Activity 9...
Page 106: ......