PUB. NO. DFNDRB JANUARY 2013
11
DEFENDER
™
NOTE: The Guardian Defender may be wired directly
into the workstation control system.
1.
The following is the responsibility of the installing
electrician.
a. All local, state, and national electrical codes are met.
b. Electrical service up to the control box with proper
branch service protection and an approved means of
disconnect.
2.
All necessary wiring diagrams are on
Pages 26 - 35.
4.
Rite-Hite provided control boxes are equipped with class
CC protective fusing for the incoming power.
5.
The incoming power terminals in the control box will not
accommodate wires larger than 10AWG.
6.
All routing and securing of cables is the responsibility of
the end user / installer.
CONTROL BOX INSTALL - FEATURE RICH
1.
Install control box and remote disconnect (supplied by
others), approximately 54" [1372] above floor level.
2.
Installation of conduit from motor junction box to control
box and remote disconnect to be determined by end user.
All connections to control box must be through the
bottom.
3.
Make sure cables do not interfere with moving parts.
4.
Strip and trim wires to proper length and connect to
terminal strip as shown on
Pages 26 - 35.
NO CONTROL BOX INSTALL
1.
Assemble components necessary to control 3 phase
power at either 220, 208, 230, 400, 460 or 575 volts.
2.
Follow wiring diagram on
Pages 26 - 35
to connect motor
and control wiring.
3.
The brake is controlled by an IR current sensing relay so
there are no separate brake wires.
POWER UP/START UP (Completed after limits set)
1.
Turn on power to the control box and position the curtain
in the center of its travel.
2.
Press the OPEN button, the roller should turn so that if
the curtain hanging on the back side it would be raised. If
roller turns the wrong way, immediately stop the door.
3.
To reverse the phase, disconnect power, lock and tag out.
Reverse leads L1 and L2 in the control box. Reconnect
power and check operation.
4.
Press the CLOSE button, the roller should turn so that if
the curtain was hanging on the back side it would be
lowered. If roller turns the wrong way, immediately stop
the door.
ELECTRICAL INSTALLATION
When working with electrical or electronic controls, make sure
that the power source has been locked out and tagged according
to OSHA regu la tions and approved local electrical codes.
W A R N I N G ! ! !
!
A qualified electrician should install the wiring in accordance with
local and national electrical codes. Use lockout and tagout
procedures to avoid injury.
I M P O R T A N T ! ! !
When drilling holes in the box, DO NOT turn control box upside
down or go too deeply into the box. Damage or debris may fall into
electrical components causing failure or severe equipment damage.
C A U T I O N ! ! !
!
To reduce risk of injury or death, an earth ground connection
MUST BE made to the green/yellow control box ground terminal. If
metal conduit is used as the ground connector, an N.E.C. approved
ground bushing and green/yellow wire MUST BE properly attached
to the conduit for connection to the ground terminal.
I M P O R T A N T ! ! !
Feature Rich - Control Box Mounting
11.1
Incoming Power
All holes and conduit run into the control
box must be through the bottom.
54" [1372]
DO NOT DRILL HOLES ON TOP OF CONTROL BOX TO RUN
CONDUIT, AS DUST PARTICLES AND MOISTURE MAY CAUSE
DAMAGE TO ELECTRICAL COMPONENTS.
THE SAFEST LOCATION IS AT THE BOTTOM. FAILURE TO DO SO,
WILL VOID WARRANTY
W A R N I N G ! ! !
!
Remove labels after installation is complete
Summary of Contents for FROMMELT SAFETY PRODUCTS GUARDIAN DEFENDER
Page 4: ...4 PUB NO DFNDRB JANUARY 2013 DEFENDER GUIDE BASE PLATE POSITIONS ...
Page 18: ...18 PUB NO DFNDRB JANUARY 2013 DEFENDER FEATURE RICH I COMM SETTINGS ...
Page 45: ...PUB NO DFNDRB JANUARY 2013 45 DEFENDER ARCHITECTURAL DRAWING DIRECT DRIVE ...
Page 46: ...46 PUB NO DFNDRB JANUARY 2013 DEFENDER ARCHITECTURAL DRAWING DIRECT DRIVE II ...
Page 47: ...PUB NO DFNDRB JANUARY 2013 47 DEFENDER ARCHITECTURAL DRAWING CHAIN DRIVEN ...