Sending commands to all connected NA-42 units
When sending commands to all connected units, only commands for chang-
ing settings are allowed.
1. Send the RMT1FF command from the computer to set all NA-42
units to remote mode (link established).
2. Use the necessary setting commands to control all NA-42 units.
3. Send the RMT0FF command from the computer to set all NA-42
units to local mode (link terminated).
To use data request commands or to change the settings of one unit
only, follow the steps described in “Sending commands to a single
unit” on the preceding page.
(Setting change command) <
CR
><
LF
>
NA-42
Computer
Establish linked condition
Change setting
Terminate linked condition
RMT1FF<
CR
><
LF
>
RMT0FF<
CR
><
LF
>
Note
When receiving the RMT1FF command, any NA-42
unit regardless of its ID number will go into remote
mode.
In this case, no <
ACK
>READY<
CR
><
LF
> response