C199 Manual
59
Temperatures Available with a Controller
The water heater can deliver water at only one temperature setting at a time. The available temperatures are
provided below. A temperature lower than 98° F (37° C) can be obtained at the tap by mixing with cold water.
To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the “On/Off” button
for 5 seconds while the water heater is OFF.
These temperatures are suggestions only:
*
These models have a default maximum temperature of 140° F (60° C) and an option (SW5 and SW6) to
increase the maximum temperature to 185 °F (85 °C). Default: SW5 is OFF and SW6 is ON in DIPSW1.
DO NOT adjust the other switches unless specifically instructed to do so.
WARNING
Kitchen 120 °F (49° C)
Shower 98 - 110 °F (37 - 43 °C)
Bath Fill 102 - 110 °F (39 - 43 °C)
Temperature Settings Available with MC-91-2
Fahrenheit °F
98 100 102 104 106 108 110 115 120
125
*
130
*
135
*
140
*
150
**
160
**
185
**
Celsius °C
37
38
39
40
41
42
43
46
49
52
54
57 60
66
71
85
** These settings require SW5 and SW6 in DIPSW1 to be in the ON position.
Alternate Temperature Settings
A different range of temperature settings is available by setting SW2 to OFF and SW3 to ON in the DIPSW 2.
The table below shows the settings available with the MC-91-2 controller. Default: SW2 is ON and SW3 is OFF in
DIPSW2.
Alternate Temperature Settings Available with MC-91-2
Fahrenheit °F
110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185
Celsius °C
43
46
49
52
54
57 60
63
66
68
71
74
77
79
82
85
MC-91-1, MCC-91-1, MC-100V-1, and BC-100V-1 controllers are not compatible with
Alternate Temperature Settings. Alternate Temperature Settings are for commercial
applications only.
DO NOT use the MC-91-1, MCC-91-1, MC-100V-1, or BC-100V-1 controllers when SW2 is
OFF and SW3 is ON in DIPSW 2.
WARNING