34
C199 Manual
The following information should be used in conjunction
with the IPEX System 636 Installation Guide:
Termination kits are to be tested and certified for use
with the brand of pipe-fitting-cement system that is to
be utilized in the application. The IPEX Low Profile
termination is fully certified for use with IPEX product
only.
System 636 PVC Low Profile Vent kits are rated to 65°C
maximum and are made from certified compound.
All termination kits must be located and installed in
accordance with these instructions, local building code,
and CSA B149.1 Natural Gas and Propane Installation
Code.
All exhaust vents and air inlets must terminate at the same
height to avoid property damage, personal injury, or death.
3” and 4” Low Profile Vent Termination Kits
Certified PVC/CPVC Vent Termination Options (continued)
Installation:
1. Once a proper location has been determined, cut 2
appropriately sized holes in the wall to accommodate
the pipe. (Reference the Low Profile Termination
Kit-Dimensions table below)
2. Slide intake and exhaust pipes through the holes.
Secure (using solvent cement) both pipes to the base
of the vent termination kit. (Be sure to follow
guidelines for solvent cementing as described in the
System 696 Installation Guide)
3. Use the supplied screws and anchors to secure the
base to the wall. (a drilled 3/16” hole, 1-3/16” deep
will be needed for the anchors.) Use the base as a
template to locate the anchor hole.
4. Using the supplied screws, secure the Cap to the Base.
5. Upon securing the vent termination and pipes, seal the
wall penetrations (from the interior) using a PVC
compatible sealant material.
Item #
Description
Pipe Outside
Diameter
Hole Spacing
196985 3” Flush Mount
3.5”
5.6”
196986 4” Flush Mount
4.5”
5.6”
Low Profile Termination Kits-Dimensions
Qty
Item Description
1
Base (Two Holes)
1
Cap (One Hole)
8
Stainless Steel Screws
4
Plastic Anchors
Kit Contents
Air Piping
Vent Piping
Vent Base
Vent Cap
Vent
Air
Vent / Air
Termination
12” Min Between Edge of Air
Inlet and Adjacent Vent Outlet
WARNING
From Water Heater Vent
Pipe Connection
To Water Heater Intake Air
Connection
12” min
Vent / Air
Termination
Orientations
Grade or
Snow Line
Summary of Contents for c199e
Page 54: ...54 C199 Manual Ladder Diagram ...
Page 143: ...72 C199 Manual ...
Page 144: ...U306 1971 00 100000380 2 2015 ...