INDEX
3 / 191
5-6-3 Checking the version of the main unit (84D VER).................................................................. 60
5-6-4 Checking the sensor versions (SEN VER) ............................................................................. 61
5-6-5 Checking the communication PCB version (NET VER)
................................ 61
5-7 Shutting down .................................................................................................................................... 62
6.
Alarm Activation ....................................................................................................................................... 63
6-1 Gas (oxygen) alarm pattern ............................................................................................................... 63
6-1-1 Alarm Activation ...................................................................................................................... 63
6-1-2 Contact operation (auto reset)
...........................................................
64
6-1-3 Contact operation (self-latching)
........................................................
65
6-1-4 Response when a gas alarm is triggered ............................................................................... 68
6-2 Fault alarm patterns ........................................................................................................................... 69
6-3 External output operations ................................................................................................................. 70
6-4 Various functions to ensure proper alarm activation .......................................................................... 73
6-4-1 Zero suppression function ...................................................................................................... 73
6-4-2 Zero follower function ............................................................................................................. 74
6-4-3 Sensitivity correction function ................................................................................................. 74
6-4-4 Calibration history, alarm trend history, and event history functions ...................................... 75
6-4-5 Automatic sensor recognition function ................................................................................... 75
7.
Maintenance ............................................................................................................................................. 77
7-1 Maintenance intervals and maintenance items ................................................................................. 77
7-2 Performing alarm tests ....................................................................................................................... 79
7-3 Maintenance (regular maintenance) mode ........................................................................................ 81
7-3-1 Maintenance mode setting items ........................................................................................... 81
7-3-2 Switching to maintenance mode ............................................................................................ 82
7-4 Performing a gas introduction test ..................................................................................................... 84
7-5 Performing calibration ........................................................................................................................ 85
7-5-1 Running zero calibration ......................................................................................................... 85
7-5-2 Running span adjustment ....................................................................................................... 87
7-5-3 Connecting the calibration gas ............................................................................................... 90
7-5-4 Disconnecting the calibration gas .......................................................................................... 92
7-6 Adjusting the flow ............................................................................................................................... 93
7-6-1 Checking the flow (FLOW) ..................................................................................................... 93
7-6-2 Manually adjusting the flow (FLOW) ...................................................................................... 94
7-6-3 Correcting the flow value (DEF FLOW) .................................................................................. 95
7-7 Checking setting values (maintenance mode) ................................................................................... 96
7-7-1 Checking the date last calibrated (LAST CAL) ....................................................................... 96
7-7-2 Checking the set potential (E VOLT) ...................................................................................... 97
7-7-3 Checking the temperature of the detector (TEMP) ................................................................ 97
7-8 Setting the initial date of sensor use (S SET) .................................................................................... 98
7-9 Making changes in Environmental setting 1 ...................................................................................... 99
7-9-1 INHIBIT setting (INHIBIT) ....................................................................................................... 99
7-9-2 Alarm setpoints (ALM P) ....................................................................................................... 101
7-9-3 Alarm delay time setting (ALM DLY) ..................................................................................... 103
7-9-4 Fault alarm tests (F TEST) ................................................................................................... 104
7-9-5 Terminal unit settings (OPT ACT)
..................................................... 106
7-10 Making changes in Environmental setting 2 .................................................................................. 107
7-10-1 Date and time setting (DAY TIME) ..................................................................................... 108
7-10-2 Zero suppression value setting (SUPPRESS) ................................................................... 110
7-10-3 Zero suppression type setting (SUP TYPE) ....................................................................... 111
7-10-4 Settings for contacts during alarm tests (TEST RLY)
.................... 113
ET
EA
4-20mA
EA
4-20mA
EA
4-20mA
EA
4-20mA
EA
Summary of Contents for GD-84D-EX Series
Page 192: ...Revision History Issue Revision details Issue date 0 First issue PT2 3041 12 20 2022 ...
Page 193: ......