57
RIELLOTECH CLIMA TOP - CLIMA COMFORT
RIELLOTECH CLIMA TOP - CLIMA COMFORT
Operat-
ing line
User
level Function
Default value
Min
Max
Unit
7730
I
Outside temp B9
-
-50,0
50
°C
7732
I
Flow temp B1
-
0,0
140
°C
7734(***)
I
Flow temp B12
-
0.0
140
°C
7750
I
DHW temp B3
-
0,0
140
°C
7760
I
Boiler temp B2
-
0,0
140
°C
7780(**)
F
Output test UX21 module 1
- - -
- - -/ 0
100
%
7781(**)
F
Output signal UX21 module 1
0
0
100
-
7781(**)
F
[Output signal UX21 module 1]
None ¦ Closed (ooo), Open (- - -) ¦ Pulse ¦ Frequency Hz ¦ Voltage V
¦ PWM %
None
-
-
-
7782(**)
F
Output test UX22 module 1
- - -
- - -/ 0
100
%
7783(**)
F
Output signal UX22 module 1
0
0
100
-
7783(**)
F
[Output signal UX22 module 1]
None ¦ Closed (ooo), Open (- - -) ¦ Pulse ¦ Frequency Hz ¦ Voltage V
¦ PWM %
None
-
-
-
7784(**)
F
Output test UX21 module 2
- - -
- - -/ 0
100
%
7785(**)
F
Output signal UX21 module 2
0
0
100
-
7785(**)
F
[Output signal UX21 module 2]
None ¦ Closed (ooo), Open (- - -) ¦ Pulse ¦ Frequency Hz ¦ Voltage V
¦ PWM %
None
-
-
-
7786(**)
F
Output test UX22 module 2
- - -
- - -/ 0
100
%
7787(**)
F
Output signal UX22 module 2
0
0
100
-
7787(**)
F
[Output signal UX22 module 2]
None ¦ Closed (ooo), Open (- - -) ¦ Pulse ¦ Frequency Hz ¦ Voltage V
¦ PWM %
None
-
-
-
7788(**)
F
Output test UX21 module 3
- - -
- - -/ 0
100
%
7789(**)
F
Output signal UX21 module 3
0
0
100
-
7789(**)
F
[Output signal UX21 module 3]
None ¦ Closed (ooo), Open (- - -) ¦ Pulse ¦ Frequency Hz ¦ Voltage V
¦ PWM %
None
-
-
-
7790(**)
F
Output test UX22 module 3
- - -
- - -/ 0
100
%
7791(**)
F
Output signal UX22 module 3
0
0
100
-
7791(**)
F
[Output signal UX22 module 3]
None ¦ Closed (ooo), Open (- - -) ¦ Pulse ¦ Frequency Hz ¦ Voltage V
¦ PWM %
None
-
-
-
7820
I
Sensor temp BX1
-
-28,0
350
°C
7821
I
Sensor temp BX2
-
-28,0
350
°C
7822(***)
I
Sensor temp BX3
0
-28
350
°C
7823(***)
I
Sensor temp BX4
0
-28
350
°C
7830
I
Sensor temp BX21 module 1
0
-28
350
°C
7831
I
Sensor temp BX22 module 1
0
-28
350
°C
7832
I
Sensor temp BX21 module 2
0
-28
350
°C
7833
I
Sensor temp BX22 module 2
0
-28
350
°C
7834(**)
I
Sensor temp BX21 module 3
0
-28
350
°C
7835(**)
I
Sensor temp BX22 module 3
0
-28
350
°C
7840(***)
I
Voltage signal H1
-
0
10
Volt
7841(***)
I
Contact state H1
Open ¦ Closed
-
-
-
-
7844(**)
F
Input signal H1
0
0
65535
-
7844(**)
F
[Output signal H1]
None ¦ Closed (ooo), Open (- - -) ¦ Pulse ¦ Frequency Hz ¦ Voltage V
None
-
-
-
7845
F
Input signal H2 module 1
0
0
65535
-
7845(**)
F
[Output signal H2 module 1]
None ¦ Closed (ooo), Open (- - -) ¦ Pulse ¦ Frequency Hz ¦ Voltage V
None
-
-
-
7845(**)
F
Input signal H21 module 1
0
0
65535
-
7845
F
[Output signal H21 module 1]
None ¦ Closed (ooo), Open (- - -) ¦ Pulse ¦ Frequency Hz ¦ Voltage V
None
-
-
-
7846
F
Input signal H22 module 1
0
0
65535
-
7846(**)
F
[Output signal H22 module 1]
None ¦ Closed (ooo), Open (- - -) ¦ Pulse ¦ Frequency Hz ¦ Voltage V
None
-
-
-
7847(**)
F
Input signal H2 module 2
0
0
65535
-
7847(**)
F
[Output signal H2 module 2]
None ¦ Closed (ooo), Open (- - -) ¦ Pulse ¦ Frequency Hz ¦ Voltage V
None
-
-
-