33
RIELLOTECH CLIMA TOP - CLIMA COMFORT
RIELLOTECH CLIMA TOP - CLIMA COMFORT
RIELLOtech CLIMA TOP - CLIMA COMFORT
21
LIST OF PARAMETERS
9
IMPORTANT! The following parameter descriptions
may differ from those on the controller for rea-
sons of abbreviation or program version.
User legend:
E: End user
O: OEM
I: Start-up technician
F: Installer
OL: Parameter number
Legend:
(*)
QAA75../78 only
(**) RIELLOtech CLIMA COMFORT only
(***) RIELLOtech CLIMA TOP only
Operat-
ing line
User
level Function
Default value
Min
Max
Unit
Time of day and date
1
E
Hours/minutes
-
00:00
23:59
hh:mm
2
E
Day / month
-
1,01
31,12
dd.MM
3
E
Year
-
2004
2099
yyyy
5
F
Start of summertime
25,03
1,01
31,12
dd.MM
6
F
End of summertime
25,10
1,01
31,12
dd.MM
Operator unit
20
E
Language
German ¦ …
German
-
-
-
21
O
Display of special operation
Off ¦ On
On
-
-
-
22
F
Info
Temporarily ¦ Permanently
Temporary
-
-
-
26
F
Operation lock
Off ¦ On
Off
-
-
-
27
F
Programming lock
Off ¦ On
Off
-
-
-
29(**)
E
Units
(°C,bar ¦ °F,PSI)
°C,bar
-
-
-
30
O
Save basic settings
No ¦ Yes
No
-
-
-
31
O
Activate basic settings
No ¦ Yes
No
-
-
-
32(**)
E
Basic setting
Compatible
-
-
-
39(**)
E
Commissionig menù (On¦Off)
Off
-
-
-
40(*)
I
Used as
Room unit 1 ¦ Room unit 2 ¦ Room unit 3 ¦ Operator unit 1 ¦ Opera-
tor unit 2 ¦ Operator unit 3 ¦ Service unit
Room unit 1
-
-
-
42(*)
I
Assignment device 1
Heating circuit 1 ¦ Heating circuit 1 and 2 ¦ Heating circuit 1 and 3 ¦
All heating circuits
Heating circuit 1
-
-
-
44
I
Operation HC2
Commonly with HC1 ¦ Independently
Commonly with HC1
-
-
-
46
I
Operation HC3
Commonly with HC1 ¦ Independently
Commonly with HC1
-
-
-
48(*)
I
Action occupancy button
None ¦ Heating circuit 1 ¦ Heating circuit 2 ¦ Commonly
Heating circuit 1
-
-
-
54(*)
F
Readjustment room sensor
0,0
-3
3
°C
70
F
Software version
-
0
99,9
-
Time prog heating circuit 1
500
E
Preselection
Mo - Su ¦ Mo - Fr ¦ Sa - Su ¦ Mo ¦ Tu ¦ We ¦ Th ¦ Fr ¦ Sa ¦Su
Mo - Su
-
-
-
501
E
1st phase on
6:00
00:00
24:00
hh:mm
502
E
1st phase off
22:00
00:00
24:00
hh:mm
503
E
2nd phase on
24:00
00:00
24:00
hh:mm
504
E
2nd phase off
24:00
00:00
24:00
hh:mm
505
E
3rd phase on
24:00
00:00
24:00
hh:mm
506
E
3rd phase off
24:00
00:00
24:00
hh:mm
516
E
Default values
No ¦ Yes
No
-
-
-
Time prog heating circuit 2
520
E
Preselection
Mo - Su ¦ Mo - Fr ¦ Sa - Su ¦ Mo ¦ Tu ¦ We ¦ Th ¦ Fr ¦ Sa ¦Su
Mo - Su
-
-
-
521
E
1st phase on
6:00
00:00
24:00
hh:mm
522
E
1st phase off
22:00
00:00
24:00
hh:mm