27
RIELLOTECH CLIMA TOP - CLIMA COMFORT
RIELLOTECH CLIMA TOP - CLIMA COMFORT
18
MODE SELECTION
Press the central heating mode button (5) to select the various
modes. The active mode is shown by a line under the corre-
sponding symbol.
5
Boiler temperature
Automatic
s
In automatic mode, room temperature is controlled by the timer
program:
Characteristics:
− Central heating operates according to the timer program
− The temperature setpoint is set to comfort "
o
" or re-
duced "
l
"
− All protection functions are active
− Summer/winter switching is automatic (ECO functions).
Continuous operation of central heating is limited to 24h
Continuous
o
o
l
In continuous mode, room temperature is controlled on the ba-
sis of the comfort/reduced setting:
o
Central heating set to comfort setpoint
l
Central heating set to reduced setpoint
Characteristics:
− Central heating is continuously on with no time program
− All protection functions are active
− Summer/winter switching is automatic (ECO functions).
Continuous central heating idle time is limited to 24h (see
parameter 730).
Protection
b
In protection mode the central heating is switched off, but the
system remains protected against frost (provided the electrical
supply remains switched on).
Characteristics:
− Central heating is switched off
− Temperature is set to the frost protection setpoint
− All protection functions are active
− Summer/winter switching is automatic (ECO functions).
Continuous operation of central heating is limited to 24h
Cooling mode (if relevant)
t
The "cooling“ function controls room temperature on the basis
of the timer program.
Characteristics:
− Manual mode
− Cooling according to timer program
− Temperature setpoint according to “cooling to comfort
setpoint”
− All protection functions are active
− Limitation of cooling on the basis of outdoor temperature
− Summer compensation
Domestic Hot Water (DHW)
v
Press the central heating mode button (3) to activate DHW pro-
duction.
A line appears under the corresponding symbol.
3
Boiler temperature
ON
DHW is generated according to the timer program
(params. 560 to 566)
OFF
DHW production is switched off but the protection
functions remain active
9
You can force DHW production (PUSH function) by pressing
and holding the DHW button (3) for at least 3 seconds.
Setting the room temperature setpoint
Turn the knob (14) to set the desired room temperature comfort
setpoint.
14
13
6
Comfort setpoint
To set reduced room temperature:
− Press "
K
" (13)
− Select “Heating circuit 1”
− Set the room temperature reduced setpoint.
9
After changing a setpoint, you need to wait about 2 hours
for the new setting to have any effect on room temperature.
9
If no room unit is installed, changing the room temperature
setpoint simply shifts the heating curve.