FAMILY CONDENS IS E
18
ENGLISH
19
SCENARIO A
temporary
fault
definitive
fault
Scenario B
the RESET icon will appear along with a different alarm code, togeth-
er with the
.
In this case, proceed as described in point 3.
SCENARIO B
temporary
fault
definitive
fault
Mode C
- together with the
, alarm code 91 will appear (see description
below).
- The intervention of the Technical Assistance Service is required.
- The boiler is equipped with an auto-diagnostic system which,
based on the total number of hours in certain operating conditions,
can signal the need to clean the primary exchanger (alarm code
91).
- Once the cleaning operation has been completed, reset to zero the
total hour meter with special kit supplied as an accessory following
procedure indicated below:
- Switch off the power supply
- Remove the electric casing by means of the screws and fixing
hooks
- Extract the connector J13 (see wiring diagram)
- Power up the boiler and wait for alarm 13 to appear on the display
- Disconnect the power supply and reconnect connector J13
- Refit the electric casing and restore the boiler's function.
NOTE: the meter resetting procedure should be carried out after
each in-depth cleaning of the primary exchanger or if this latter is
replaced.
2. Display only of the RESET icon
Press the
key to restore operation. If the boiler performs the fir-
ing procedure and resumes normal operation, the stoppage can be
attributed to a chance situation.
Repeated lockouts require the intervention of the Riello Techni-
cal Assistance Centre .
3. Display of the RESET and
icons
The intervention of the Riello Technical Assistance Centre is required.
Fault on DHW circuit probe - 60
The fault code is only displayed in standby.
Fault J0 (card/interface connection): check that the electrical con-
nections are correct. If the fault persists after the control, contact the
Riello Technical Assistance Centre.
Fault J1 (without card/remote control panel connection): to re-
store the operation, press key
again and then key
until the
normal operation is restored.
Code
Fault description
RESET
icon
Icon
10
Flame failure lockout (D)
YES
NO
11
False flame (D)
NO
YES
12
NEW ATTEMPT IN PROGRESS (T)
NO
NO
13
MINIMUM GAS INPUT PRESSURE (T)
NO
YES
14
MINIMUM GAS INPUT PRESSURE (D)
YES
NO
20
LIMIT THERMOSTAT (D)
YES
NO
21
FLUE GAS PROBE SHORT CIRCUIT (D)
YES
YES
24
DELIVERY PROBE LIMIT
TEMPERATURE (D)
YES
NO
25
DELIVERY PROBE LIMIT
TEMPERATURE (T)
NO
YES
26
RETURN PROBE LIMIT
TEMPERATURE (D)
YES
NO
27
RETURN PROBE LIMIT
TEMPERATURE (T)
NO
YES
28
RETURN-DELIVERY PROBE
DIFFERENTIAL (D)
YES
YES
29
FLUE GAS PROBE OVER-
TEMPERATURE (D)
YES
YES
34
FAN (cycle start) (D)
YES
NO
37
FAN CYCLE IN PROGRESS
(high rpm) (D)
YES
YES
40
INSUFFICIENT SYSTEM
PRESSURE (D**)
YES
NO
41
INSUFFICIENT SYSTEM
PRESSURE (T**)
NO
YES
42
WATER PRESSURE TRANSDUCER (D)
YES
YES
50-59
ELECTRONIC CARD (D)
YES
YES
60
DHW PROBE 1 (T) (°)
NO
YES
70
PRIMARY PROBE SHORT
CIRCUIT/OPEN (D)
YES
YES
71
DELIVERY PROBE OVER-
TEMPERATURE (T)
NO
NO
72
RETURN PROBE SHORT
CIRCUIT/OPEN (D)
YES
YES
75
SECOND HEATING SYSTEM
PROBE ABSENT
NO
YES
77
LOW TEMPERATURE THERMOSTAT (T)
NO
YES
78
DELIVERY/RETURN DIFFERENTIAL (T)
NO
YES
79
DELIVERY/RETURN DIFFERENTIAL (D)
YES
NO
80
SYSTEM FAULT (D)
YES
YES
81
SYSTEM FAULT (T)
NO
YES
82
SYSTEM FAULT (D)
YES
YES
83
SYSTEM FAULT (T)
NO
YES
89
STOP SIGNAL SENT TO
THE OT DEVICES
-
-
91 (-)
PRIMARY HEAT EXCHANGER
CLEANING (-)
NO
YES
J0
CONNECTION FAILURE BETWEEN
INTERFACE AND MAIN CARD
-
-
J1
CONNECTION FAILURE WITH THE
REMOTE CONTROL PANEL
-
-
Summary of Contents for FAMILY CONDENS 2.5
Page 3: ...FAMILY CONDENS IS E 3...
Page 68: ...FAMILY CONDENS IS E 68 M R AF G AC 9 11...
Page 70: ...FAMILY CONDENS IS E 70 A C B D 1 2 3 4 5 7 9 11 12 13 10 F E 6 8 14 15...
Page 86: ...FAMILY CONDENS IS E 86 fig 29 fig 32 fig 31 fig 30 B A C D...
Page 87: ......
Page 88: ...Cod 20120920 05 16 Ed 0...