FAMILY CONDENS IS E
14
The
FAMILY CONDENS IS E boiler is supplied for use with
methane gas (G20) or LPG (G31) and are already factory set as
specified on the rating plate, so do not require any calibration.
All checks must be carried out exclusively by the Riello Techni-
cal Assistance Service.
A
B
A
4.4
Parameter programming
This boiler is fitted with the latest type of electronic cards, allowing
you to set/modify the machine operating parameters and thereby of-
fering a more personalised configuration to meet the various system
and/or user needs.
The programmable parameters are the ones indicated in the table.
The parameter programming operations must be carried out
with the boiler in the OFF position. To do this, press the
key
until you see "ENERGY FOR LIFE" on the display.
During the parameter modification operations, the
key
acts as an ENTER key (Confirm), while the key acts as an
ESC key (Exit).
If no confirmation is given within 10 seconds, the value is not
stored and the previous one is indicated again.
Setting the password
The programming of the parameters is accessed by pressing the
key and then pressing the
key for 3 seconds.
PROG appears on the display followed by CODE.
Press the ENTER key to confirm.
Enter the programming access code to the parameters editing func-
tions rotating the encoder until the necessary value is obtained.
Confirm the programming code by pressing the ENTER key.
The programming access password is located inside the command
panel.
ENTER
ESCAPE
Modifying the parameters
Turn the encoder A to scroll the two digit codes of the parameters
indicated in the table.
A
Identify the parameter you want to modify in the following way:
- press the ENTER key to be able to modify the parameter value.
- The previously set value will flash when the ENTER key is pressed
- turn the encoder A to the desired value
- confirm the new value by pressing ENTER. The digits will stop
flashing
- quit by pressing ESCAPE
The boiler will switch off, press the
key to restore the operation.
Summary of Contents for FAMILY CONDENS 2.5
Page 3: ...FAMILY CONDENS IS E 3...
Page 68: ...FAMILY CONDENS IS E 68 M R AF G AC 9 11...
Page 70: ...FAMILY CONDENS IS E 70 A C B D 1 2 3 4 5 7 9 11 12 13 10 F E 6 8 14 15...
Page 86: ...FAMILY CONDENS IS E 86 fig 29 fig 32 fig 31 fig 30 B A C D...
Page 87: ......
Page 88: ...Cod 20120920 05 16 Ed 0...