FAMILY CONDENS IS E
34
TECHNICAL DATA
DESCRIPTION
FAMILY CONDENS IS E
2.5 IS E
3.0 IS E
3.5 IS E
Fuel
G20
G31
G20
G31
G20
G31
Appliance category
●
Country of destination
II2H3P
● (+)
Type of appliance
B23P-B53P-C13,C13x-C33,C33x-C43,C43x-C53,C53x-C83,C83x-C93,C93x, 3CEP
Heating
Nominal heat input
20,00
25,00
30,00
kW
Nominal heat output (80°/60°)
19,62
24,58
29,25
kW
Nominal heat output (50°/30°)
21,44
26,70
31,77
kW
Reduced heat input
2,80
4,00
3,20
4,50
3,60
5,00
kW
Reduced heat output (80°/60°)
2,76
3,95
3,16
4,45
3,50
4,87
kW
Reduced heat output (50°/30°)
3,00
4,20
3,44
4,74
3,80
5,29
kW
Nominal Range Rated thermal output (Qn)
20,00
25,00
30,00
kW
Minimum Range Rated thermal output (Qm)
6,00
6,00
6,00
6,00
3,60
5,00
kW
Heat./DHW. Heat input at minimum with
installation in positive pressure smoke pipe
2,8
4,0
3,2
4,5
3,6
5,0
kW
Domestic hot water
Nominal heat input
25,00
30,00
34,60
kW
Nominal heat output (*)
25,00
30,00
34,60
kW
Reduced heat input
2,80
4,00
3,20
4,50
3,60
5,00
kW
Reduced heat output (*)
2,80
4,00
3,20
4,50
3,60
5,00
kW
Useful efficiency Pn max - Pn min (80°/60°)
98,1-98,7
98,4-98,8
98,3-98,9
98,5-98,8
97,5-97,2
96,5-97,3
%
Useful efficiency 30% (47° return)
102,4
100,7
103,3
100,6
102,8
-
%
Useful efficiency Pn max - Pn min (50°/30°)
107,2-107,0
104,6-104,9
106,8-107,6
104,8-105,3
105,9-105,6
-/105,7
%
Useful efficiency 30% (30° return)
109,6
107,3
109,6
107,5
109,2
106,4
%
Efficiency at average P Range Rated (80°/60°)
98,4
-
98,3
-
97,8
-
%
Combustion efficiency
98,3
98,6
97,6
%
Heating maximum gas capacity
2,12
-
2,64
-
3,17
-
Sm
3
/h
-
1,55
-
1,94
-
2,33
kg/h
DHW maximum gas capacity
2,64
-
3,17
-
3,66
-
Sm
3
/h
-
1,94
-
2,33
-
2,69
kg/h
Heating minimum gas capacity
0,30
-
0,34
-
0,38
-
Sm
3
/h
-
0,31
-
0,35
-
0,39
kg/h
DHW minimum gas capacity
0,30
-
0,34
-
0,38
-
Sm
3
/h
-
0,31
-
0,35
-
0,39
kg/h
Residual discharge head of boiler without pipes
80
125
160
Pa
Collective smoke pipes under pressure
(with specific accessory only)
G20
G31
G20
G31
G20
G31
Maximum allowed pressure in smoke pipe in
the event of installation with
collective smoke pipe
50
50
50
50
50
50
Pa
Flow rate
CH
DHW
CH
DHW
CH
DHW
CH
DHW
CH
DHW
CH
DHW
Mass flue gas flow rate maximum output
9,086
11,357 9,297 11,621 11,357
13,629 11,621
13,946
13,629
15,718
13,946
16,084
g/s
Mass flue gas flow rate minimum output
1,272
1,272
1,859
1,859
1,454
1,454
2,092 2,092 1,635 1,635
2,324
2,324
g/s
Air capacity
24,298 30,372 24,819 31,024 30,372
36,447
31,024 37,228
36,447
42,035
37,228
42,937
Nm
3
/h
Flue gas capacity
26,304 32,880 26,370 32,963 32,880
39,456
32,963 39,555
39,456
45,506
39,555
45,620
Nm
3
/h
Air excess index ( ) maximum output
1,269
1,269
1,341
1,341
1,269
1,269
1,341 1,341 1,269 1,269
1,341
1,341
Air excess index ( ) minimum output
1,269
1,269
1,341
1,341
1,269
1,269
1,341 1,341 1,269 1,269
1,341
1,341
CO
2
at maximum**/minimum**
9,00/9,00
10,00/10,00
9,00/9,00
10,00/10,00
9,00/9,00
10,00/10,00
%
CO S.A. at maximum**/minimum** lower than
150/10
190/20
150/5
180/5
150/5
160/15
ppm
NOx S.A. at maximum**/minimum** lower than
30/25
30/35
30/30
28/40
20/15
25/30
ppm
Flue gases temperature (max/min output)
67/57
67/55
69/59
69/59
70/60
71/57
°C
NOx class
5
5
5
Heating operation
Heating maximum operating pressure
3
3
3
bar
Minimum pressure for standard operation
0,25-0,45
0,25-0,45
0,25-0,45
bar
Maximum permissible temperature
90
90
90
°C
Selection field of the heating water temperature
20-80
20-80
20-80
°C
Pump head available to the system
334
334
334
mbar
for system capacity
1.000
1.000
1.000
l/h
Expansion tank
10
10
10
l
Expansion tank precharge
1
1
1
bar
Summary of Contents for FAMILY CONDENS 2.5
Page 3: ...FAMILY CONDENS IS E 3...
Page 68: ...FAMILY CONDENS IS E 68 M R AF G AC 9 11...
Page 70: ...FAMILY CONDENS IS E 70 A C B D 1 2 3 4 5 7 9 11 12 13 10 F E 6 8 14 15...
Page 86: ...FAMILY CONDENS IS E 86 fig 29 fig 32 fig 31 fig 30 B A C D...
Page 87: ......
Page 88: ...Cod 20120920 05 16 Ed 0...