FAMILY CONDENS KIS - FAMILY CONDENS IS
3) Display of the RESET icon and
The intervention of the Technical Assistance Service is required.
Family Condens KIS: Fault on DHW circuit probe - 60
The fault code is only displayed in standby.
Family Condens IS: DHW circuit 60 probe fault (only if storage tank
with probe is connected)
The fault code is only displayed in standby.
Fault J0 (card/interface connection)
: check that the electrical connec-
tions are correct. If the fault persists after the control, contact the Technical
Assistance Centre.
Fault J1 (without card/remote control panel connection):
to restore the
operation, press key
again and then key
until the normal operation
is restored.
(D)
Definitive
(T)
Temporary. In this operating status, the boiler attempts to resolve the fault situation autonomously
(°)
See the NOTE on the previous page
(**)
If these two errors arise, check the pressure shown on the hydrometer.
If the pressure is insufficient (< 0.4 bar - red field), perform the filling operations described in the “Filling and draining the systems” chapter.
If the system pressure is sufficient (> 0.6 bar - light blue field), the fault is due to a lack of circulating water. Contact the Technical Assistance Centre.
(-)
Contact the Technical Assistance Centre.
FAULT DESCRIPTION
Alarm
code
RESET icon
Icon
FLAME FAILURE LOCKOUT (D)
10
YES
NO
PARASITE FLAME (T)
11
NO
YES
NEW ATTEMPT IN PROGRESS (T)
12
NO
NO
MINIMUM GAS INPUT PRESSURE (T)
13
NO
YES
MINIMUM GAS INPUT PRESSURE (D)
14
YES
NO
LIMIT THERMOSTAT (D)
20
YES
NO
FLUE GAS PROBE SHORT CIRCUIT (D)
21
YES
YES
DELIVERY PROBE LIMIT TEMPERATURE (D)
24
YES
NO
DELIVERY PROBE LIMIT TEMPERATURE (T)
25
NO
YES
RETURN PROBE LIMIT TEMPERATURE (D)
26
YES
NO
RETURN PROBE LIMIT TEMPERATURE (T)
27
NO
YES
RETURN-DELIVERY PROBE DIFFERENTIAL (D)
28
YES
YES
FLUE GAS OVERTEMPERATURE PROBE (D)
29
YES
YES
FAN (cycle start) (D)
34
YES
NO
FAN CYCLE IN PROGRESS (high rpm) (D)
37
YES
YES
INSUFFICIENT SYSTEM PRESSURE (D**)
40
YES
NO
INSUFFICIENT SYSTEM PRESSURE (T**)
41
NO
YES
WATER PRESSURE TRANSDUCER (D)
42
YES
YES
ELECTRONIC CARD (D)
50-59
YES
YES
DHW PROBE 1 (T) (°)
60
NO
YES
PRIMARY PROBE SHORT CIRCUIT/OPEN (D)
70
YES
YES
DELIVERY PROBE OVERTEMPERATURE (T)
71
NO
NO
RETURN PROBE SHORT CIRCUIT/OPEN (D)
72
YES
YES
SECOND HEATING SYSTEM PROBE ABSENT
75
NO
YES
LOW TEMPERATURE THERMOSTAT (T)
77
NO
YES
DELIVERY/RETURN DIFFERENTIAL (T)
78
NO
YES
DELIVERY/RETURN DIFFERENTIAL (D)
79
YES
NO
SYSTEM FAULT (D)
80
YES
YES
SYSTEM FAULT (T)
81
NO
YES
SYSTEM FAULT (D)
82
YES
YES
SYSTEM FAULT (T)
83
NO
YES
PRIMARY HEAT EXCHANGER CLEANING (-)
91 (-)
NO
YES
CONNECTION FAILURE BETWEEN INTERFACE AND MAIN CARD
J0
-
-
CONNECTION FAILURE WITH THE REMOTE CONTROL PANEL
J1
-
-