![Riello Cardin T624 Programming And User Instructions Download Page 50](http://html1.mh-extra.com/html/riello/cardin-t624/cardin-t624_programming-and-user-instructions_1459998050.webp)
M1
M2
10
10
M1
M1
M1
M2
M2
M2
END PROG.
M1
M1
M2
M2
When the gate with M1 finds the opening travel limit, the other motor M2 will begin
to move.
When the gate with M2 has opened completely (reaching the mechanical stop),
pause time memorisation will start (if automatic reclosing is not being used you
may move directly to point (6a).
Once the desired pause time has elapsed, press button P/P and motor M2 will
begin to close.
When the gate with M2 has found the closing travel limit, the other motor M1 will
begin to close.
When the gate with M1 has closed completely, the motor will stop, led LD1 will
switch off and the ECU will quit programming
Checks: force, times and stopping points. We advise you to consider inserting
deceleration points (DIP 9 set to ON) to reduce impact against the travel limits so
reducing wear and tear on the mechanical parts.
Repeat programming if you have modified the mechanical travel limits.
When the gate leaf with M1 has completely closed it will stop and start to open
automatically.
M1
M2
7
7
8
8
9
9
11
11
12
12
ADVANCED PROGRAMMING (manual)
DIP 9 ON DURING programming
for a self-learning cycle that decelerates after 5 seconds so it can find the mechanical travel
limit safely. Use this setting for long and/or heavy.
Before beginning programming check the correct settings and connections by observing the leds (det. 22, fig. A):
Led
BSC, BSA, FT1, FT2, J2 and STP
must be
LIT
.
Led
J1, PC, PA, PED and P/P
must be
OFF
.
Cut off the power to the ECU and disconnect any eventual batteries during
programming.
Release the gate leaves and move them to an almost fully open position.
Rearm the motor gears and power up the installation.
Hold down the PROG button (part. 15, fig. A) for about 3 seconds until led LD1
lights up (part. 18, fig. A)
The ECU is now in the programming stage.
Press button P/P (part. 17, fig. A) the gate with motor M2 should begin to close, if it
moves in the opening direction instead, stop programming by switching off the
power, invert the wires (21-22) of motor M2 and repeat the procedure from point
(1).
2
STOP
M1
M1
M1
M2
M2
M2
P3
P/P
LD1
PROG.
When the gate leaf with M2 has completely closed it will stop and the other motor
(M1) will begin to close.
If the motor rotates in the wrong direction, switch off the power, invert the wires of
M1 and repeat the programming procedure from point (1).
If the motors stop before reaching the travel limits, increase the power
trimmer.
2
3
4
5
6
M1
M1
M1
M2
M2
M2
M1
M2
Press P/P again when M1 has reached the desired gate delay angle, the motor will
stop for a second and then start to open again.
After this point we can manually insert the DECELERATION start points
using P/P (DIP 9 set to ON) the motor will stop for a second then start again.
Otherwise wait until the gate reaches the travel limit.
When the gate with M1 has opened completely, the motor will stop and the other
motor (M2) will start to move automatically.
After this point we can manually insert the DECELERATION start points
using P/P (DIP 9 set to ON) the motor will stop for a second then start again.
Otherwise wait until the gate reaches the travel limit.
When the gate with M2 has opened completely (reached the travel limit), the motor
will stop and the pause time memorisation will start (if automatic reclosing is not
being used you may move directly to point (11).
M1
M1
M2
M2
Once the desired pause time has elapsed, press button P/P and motor M2 will
begin to close.
Press P/P again when M2 has reached the desired gate delay angle, the motor will
stop for a second and then begin to close again.
At this point you can manually insert the DECELERATION start point using
P/P if DIP 9 is set to ON. The motor will stop for a second and then begin to
move again. Otherwise wait until the gate reaches the travel limit.
49
GB
50
M1
M2
When the gate leaf with M2 has completely closed it will stop and the other motor
(M1) will begin to close.
If the motor rotates in the wrong direction, switch off the power, invert the wires
(16-17) of M1 and repeat the programming procedure from point (1).
If the motors stop before reaching the travel limits, increase the power
trimmer.
When the gate leaf with M1 has completely closed it will stop and start to open
automatically.
5
6
M1
M2
M1
M2
4
GB
PAUSE
TIME
PAUSE
TIME