2932*
Toner Density Control Level
Adjusts the toner density control threshold level.
[0 = Normal / 1 = Dark / 2 = Light / 3 = Darker / 4 = Lighter]
Use this SP when you want to adjust the image density.
2933*
ID Sensor Control Correction
Adjusts the ID sensor control coefficient.
[0.5 to 3 / 1 / 0.1/step]
2934*
ID Sensor PWM Setting
1 Display
Displays the PWM of the ID Sensor LED.
3 Upper Limit Correction
Corrects the upper limit of the PWM for the ID
sensor LED.
[0 to 1023 / 100 / 1/step]
2935
ID Sensor Initialization
Performs the ID sensor initial setting.
Press Execute on the touch panel to start. Perform this setting after replacing or cleaning
the ID sensor.
2992*
Copies After TD Sensor Error
Selects the number of copies that can be made after a TD sensor error has been
detected. When the machine copies this amount, an SC condition will occur. If the
optional fax unit is installed, the SC condition occurs immediately regardless of the
number of prints (this is because the sender of the fax cannot check the image quality of
the printout).
[0 or 1 / 0 / -]
0:100 Pages, 1:200 Pages
2995*
ID Sensor Detection Interval
System SP Tables-2
153
4
Summary of Contents for OR-C1
Page 2: ......
Page 16: ...Effectiveness of Duplex Combine Function 352 INDEX 355 14 ...
Page 22: ...Overview Mechanical Components 1 Product Information 20 1 ...
Page 26: ...1 Product Information 24 1 ...
Page 106: ...8 Check the internal finisher operation 2 Installation 104 2 ...
Page 130: ...6 Remove the PCB cover A x 1 7 Remove the tray bar cover A x 1 2 Installation 128 2 ...
Page 174: ...3 Preventive Maintenance 172 3 ...
Page 187: ...3 Remove the paper exit cover B x 1 Output Tray 1 Open the front door A Exterior Covers 185 4 ...
Page 188: ...2 Remove the output tray A x 1 4 Replacement and Adjustment 186 4 ...
Page 235: ...5 Remove the upper gear A x1 and lower gear B x1 6 Remove the connector A x2 Paper Feed 233 4 ...
Page 282: ...4 Replacement and Adjustment 280 4 ...
Page 320: ...5 System Maintenance 318 5 ...
Page 323: ...Self Diagnostic Test Flow Chart Self Diagnostic Mode 321 6 ...
Page 325: ...Self Diagnostic Mode 323 6 ...
Page 326: ...Skewed Image Do the following to fix a skewed image problem 6 Troubleshooting 324 6 ...
Page 328: ...6 Troubleshooting 326 6 ...
Page 330: ...Checking Images with the Trimming Pattern 6 Troubleshooting 328 6 ...
Page 345: ...Sensor Locations Jam Detection 343 6 ...
Page 356: ... 6 Duplex with combine mode SP 8421 005 pages 7 Energy Saving 354 7 ...
Page 358: ......