No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
-
-
• Loose connection
• Defective HDD
• Defective controller
-
-
1. Check that the HDD is correctly connected to the controller.
2. Replace the HDD.
3. Replace the controller.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
823
B
Self-diagnostic error: NIB
[XXXX]: Detailed error code
[6101]
MAC address check sum error
The result of the MAC address check sum does not match the check sum stored in
ROM.
[6104]
PHY IC error
The PHY IC on the controller cannot be correctly recognized.
[6105]
PHY IC loop-back error
An error occurred during the loop-back test for the PHY IC on the controller.
-
Replace the controller.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
824
C
Self-diagnosis error: Standard NVRAM
The controller cannot recognize the standard NVRAM installed or detects that the
NVRAM is defective.
[1401]
• Loose connection
• Defective standard NVRAM
• Defective controller
1. Check the standard NVRAM is firmly inserted into the socket.
2. Replace the NVRAM.
3. Replace the controller
Service Call Conditions
103
3
Summary of Contents for OR-C1
Page 2: ......
Page 16: ...Effectiveness of Duplex Combine Function 352 INDEX 355 14 ...
Page 22: ...Overview Mechanical Components 1 Product Information 20 1 ...
Page 26: ...1 Product Information 24 1 ...
Page 106: ...8 Check the internal finisher operation 2 Installation 104 2 ...
Page 130: ...6 Remove the PCB cover A x 1 7 Remove the tray bar cover A x 1 2 Installation 128 2 ...
Page 174: ...3 Preventive Maintenance 172 3 ...
Page 187: ...3 Remove the paper exit cover B x 1 Output Tray 1 Open the front door A Exterior Covers 185 4 ...
Page 188: ...2 Remove the output tray A x 1 4 Replacement and Adjustment 186 4 ...
Page 235: ...5 Remove the upper gear A x1 and lower gear B x1 6 Remove the connector A x2 Paper Feed 233 4 ...
Page 282: ...4 Replacement and Adjustment 280 4 ...
Page 320: ...5 System Maintenance 318 5 ...
Page 323: ...Self Diagnostic Test Flow Chart Self Diagnostic Mode 321 6 ...
Page 325: ...Self Diagnostic Mode 323 6 ...
Page 326: ...Skewed Image Do the following to fix a skewed image problem 6 Troubleshooting 324 6 ...
Page 328: ...6 Troubleshooting 326 6 ...
Page 330: ...Checking Images with the Trimming Pattern 6 Troubleshooting 328 6 ...
Page 345: ...Sensor Locations Jam Detection 343 6 ...
Page 356: ... 6 Duplex with combine mode SP 8421 005 pages 7 Energy Saving 354 7 ...
Page 358: ......