No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
798
-06
B
Corner stapler motor error (D585)
The machine does not detect a correct signal from the stapler HP sensor while the
stapler motor is operating. The 1
st
detection failure issues a jam error, and the 2
nd
failure issues this SC code.
• Staple jam
• Motor overload
• Defective stapler motor
1. Check the connections and cables for the components mentioned above.
2. Replace the HP sensor and/or stapler motor
3. Replace the finisher main board.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
798
-07
B
Stapler movement motor error (D585)
The machine does not detect a correct signal from the stapler home position sensor
while the stapler movement motor is operating. The 1
st
detection failure issues a
jam error, and the 2
nd
failure issues this SC code.
• Motor overload
• Loose connection of the stapler home position sensor
• Loose connection of the stapler movement motor
• Defective stapler home position sensor
• Defective stapler movement motor
1. Check the connection of the stapler movement motor.
2. Check the connection of the stapler home position sensor.
3. Replace the stapler home position sensor.
4. Replace the stapler movement motor.
Service Call Conditions
97
3
Summary of Contents for OR-C1
Page 2: ......
Page 16: ...Effectiveness of Duplex Combine Function 352 INDEX 355 14 ...
Page 22: ...Overview Mechanical Components 1 Product Information 20 1 ...
Page 26: ...1 Product Information 24 1 ...
Page 106: ...8 Check the internal finisher operation 2 Installation 104 2 ...
Page 130: ...6 Remove the PCB cover A x 1 7 Remove the tray bar cover A x 1 2 Installation 128 2 ...
Page 174: ...3 Preventive Maintenance 172 3 ...
Page 187: ...3 Remove the paper exit cover B x 1 Output Tray 1 Open the front door A Exterior Covers 185 4 ...
Page 188: ...2 Remove the output tray A x 1 4 Replacement and Adjustment 186 4 ...
Page 235: ...5 Remove the upper gear A x1 and lower gear B x1 6 Remove the connector A x2 Paper Feed 233 4 ...
Page 282: ...4 Replacement and Adjustment 280 4 ...
Page 320: ...5 System Maintenance 318 5 ...
Page 323: ...Self Diagnostic Test Flow Chart Self Diagnostic Mode 321 6 ...
Page 325: ...Self Diagnostic Mode 323 6 ...
Page 326: ...Skewed Image Do the following to fix a skewed image problem 6 Troubleshooting 324 6 ...
Page 328: ...6 Troubleshooting 326 6 ...
Page 330: ...Checking Images with the Trimming Pattern 6 Troubleshooting 328 6 ...
Page 345: ...Sensor Locations Jam Detection 343 6 ...
Page 356: ... 6 Duplex with combine mode SP 8421 005 pages 7 Energy Saving 354 7 ...
Page 358: ......