1.2.3 Dirty Background Band
Vertical band?
Yes
No
Horizontal band?
Yes
No
The fusing rollers may be dirty if background only appears at the copy leading
edge.
⇒
Clean or replace fusing rollers.
Lead from development unit if bands occur at 37 mm intervals.
⇒
Check and fix the development bias leakage.
Drum scratch if the bands are at 251 mm intervals.
⇒
Clean or replace the drum.
Is the edge of the dirty background band sharp?
Yes
No
Charge corona grid may be dirty.
⇒
Clean charge corona unit.
Exposure glass or fiber optics may be dirty.
⇒
Clean the exposure glass or fiber optics.
31 December 1992
TROUBLESHOOTING FOR COPY IMAGE
6-5
Summary of Contents for FW830
Page 3: ...SECTION 1 OVERALL MACHINE INFORMATION...
Page 19: ...SECTION 2 DETAILED SECTION DESCRIPTIONS...
Page 68: ...SECTION 3 INSTALLATION...
Page 86: ...SECTION 4 SERVICE TABLES...
Page 140: ...SECTION 5 REPLACEMENT AND ADJUSTMENT...
Page 209: ...SECTION 6 TROUBLESHOOTING...
Page 223: ...74 72 73 76 75 79 85 84 83 82 80 81 86 87 88 77 78...
Page 224: ...90 89...