10.5 ID SENSOR VOLTAGE (Vsg) ADJUSTMENT
When:
1. Check Vsg at every call, and adjust Vsg if it is not within
the adjustment standard.
2. At replacement of the following parts:
•
ID sensor
•
Drum
•
RAM on the main board.
3. A toner supply problem occurs.
Purpose:
To make sure that the ID sensor works correctly.
Adjustment
Standard:
Vsg = 4.0
±
0.1 volts
Perform:
SP #33
How:
Change the light intensity of the ID sensor LED by VR104.
The Vsg voltage is displayed on the operation panel.
1. Turn off the main switch and clean the following parts:
Item No.
Section
Method
(1)
Optics (exposure glass, fiber optics
array)
Damp cotton and dry soft cloth
(2)
ID sensor
Dry cloth or blower brush
(3)
Corona wires (charge, transfer, and
separation) and casing
Dry cloth
(4)
QL, PTL,
Dry cloth or blower brush
2. Remove the middle right cover.
3. Turn on the main switch.
4. Turn on DPS101-8 on the main board to enter the SP mode.
5. Select SP#33 (See Service Program Mode Access Procedure) and press
the Copy Exit Way key.
6. Check Vsg. Adjust Vsg by turning VR104 on the main board [A] if Vsg is
not within the adjustment standard.
[A]
31 December 1992
COPY QUALITY ADJUSTMENT
5-61
Summary of Contents for FW830
Page 3: ...SECTION 1 OVERALL MACHINE INFORMATION...
Page 19: ...SECTION 2 DETAILED SECTION DESCRIPTIONS...
Page 68: ...SECTION 3 INSTALLATION...
Page 86: ...SECTION 4 SERVICE TABLES...
Page 140: ...SECTION 5 REPLACEMENT AND ADJUSTMENT...
Page 209: ...SECTION 6 TROUBLESHOOTING...
Page 223: ...74 72 73 76 75 79 85 84 83 82 80 81 86 87 88 77 78...
Page 224: ...90 89...