Main SP Modes
SM 6-49
D093/D094
Syste
m
Ma
in
te
na
n
ce
Ref
eren
ce
5169
CE Login
CTL
This SP enables and disables the CE log in mode. With this SP enabled, the
machine is in the CE (Customer Engineer/Service Technician) login mode.
In the CE login mode:
The machine power can be turned off and on in the SP mode, and it will
remain in the SP mode after power is restored.
This SP is automatically reset to "0" (disabled) after the service technician
closes the SP mode with the [Exit] soft button or after the log out timer
expires.
Note
: The Auto Logout Timer is in the "System Settings" of UserTools.
[0 to 1/0/1]
0: Disable, 1: Enable
0: CE login mode disabled.
1: CE login mode enabled.
5180
Charge Counter Method
Japan Only
CTL
This SP codes sets the charge counter method.
[0 to 1/0/1]
0: Count number of sheets by paper size
1: Count frequency by paper size
5195 Limitless
Switch
CTL
This SP selects the paper feed mode by switching between "productivity
priority" (0) and "tray priority (1). This SP operates only if the operator has
selected "Auto Paper Select".
[0 to 1 / 0 / 1]
0: Productivity priority. Switches from the current feed tray to the priority tray as
soon as the machine detects the priority tray, even if paper still remains in the
current feed tray.
1: Tray priority. Switches the feed tray only after the paper in the tray current
tray runs out of paper.
Summary of Contents for D093
Page 1: ...D093 D094 SERVICE MANUAL 006365MIU...
Page 2: ......
Page 3: ...D093 D094 SERVICE MANUAL...
Page 4: ......
Page 5: ...D093 D094 SERVICE MANUAL 006365MIU...
Page 6: ......
Page 8: ......
Page 10: ......
Page 12: ......
Page 24: ......
Page 30: ......
Page 31: ...NEW FEATURES OF D093 D094 REVISION HISTORY Page Date Added Updated New None...
Page 32: ......
Page 40: ......
Page 41: ...PRODUCT INFORMATION REVISION HISTORY Page Date Added Updated New None...
Page 42: ......
Page 51: ...Overview SM 2 9 D093 D094 Product Information 2 4 OVERVIEW 2 4 1 MACHINE GENERAL LAYOUT...
Page 53: ...Overview SM 2 11 D093 D094 Product Information 2 4 2 MECHANICAL COMPONENT LAYOUT...
Page 77: ...INSTALLATION REVISION HISTORY Page Date Added Updated New None...
Page 78: ......
Page 111: ...Roll Feeder D503 D504 SM 3 33 D093 D094 Installation...
Page 168: ......
Page 169: ...PREVENTIVE MAINTENANCE REVISION HISTORY Page Date Added Updated New None...
Page 170: ......
Page 182: ......
Page 206: ...Scanner D093 D094 5 24 SM 4 Remove CGB power pack A x 4 x2 x 2...
Page 280: ...HDD D093 D094 5 98 SM 5 10 HDD 1 Remove the controller box p 5 90...
Page 307: ...SYSTEM MAINTENANCE REFERENCE REVISION HISTORY Page Date Added Updated New None...
Page 308: ......
Page 322: ...Main SP Modes D093 D094 6 14 SM 13 Film Mode3 14 Film Mode4 15 Film Mode5...
Page 420: ......
Page 421: ...TROUBLESHOOTING REVISION HISTORY Page Date Added Updated New None...
Page 422: ......
Page 503: ...ENERGY SAVING REVISION HISTORY Page Date Added Updated New None...
Page 504: ......
Page 509: ...D093 D094 SERVICE MANUAL APPENDICES...
Page 510: ......
Page 512: ......
Page 513: ...APPENDIX SPECIFICATIONS REVISION HISTORY Page Date Added Updated New None...
Page 514: ......
Page 522: ......
Page 767: ...Printer Scanner SP Tables SM Appendix 2 245 D093 D094 Appendix SP Mode Tables...
Page 768: ......
Page 769: ...APPENDIX UP MODE REVISION HISTORY Page Date Added Updated New None...
Page 770: ......