20
1. DIP Switches
The DIP switches are used to select pull/push to open, enable/disable auto close function, enable/disable open
interval between the master and slave gate opener, enable/disable close interval between the master and slave
gate opener and enable/disable photo beam function.
DIP Switch #1: Select push/pull to open
If the gate opens into the property (
pull to open
), the DIP Switch is set to
OFF
(factory default setting). If your
gate opens out from the property (
push to open
) the DIP Switch must be set to the
ON
position.
Factory default setting is
OFF
.
DIP Switch #2: Auto close function enabled/disabled
ON
– Auto close function
enabled
OFF
– Auto close function
disabled
Set the switch #2 to ON to enable the auto close function. Factory default setting is
OFF
.
DIP Switch #3: Enable/disable open interval between the master and slave gate opener
ON
– Open interval
is enabled
OFF
–Open interval
is disabled
Factory default setting is ON.
NOTE: Open interval time can be adjusted by the OPEN DELAY potentiometer.
DIP Switch #4: Enable/disable close interval between the master and slave gate opener
ON
– Open interval
is enabled
OFF
–Open interval
is disabled
Factory default setting is ON.
NOTE: Close interval time can be adjusted by the CLOSE DELAY potentiometer.
DIP Switch #5: Photocell function enabled/disabled
ON
– Photocell function
enabled
OFF
– Photocell function
disabled
You must set the switch #5 to ON to enable the photocell function if you want to use the photocell with the gate
opener. Factory default setting is
OFF
.