16
1. Actuator 1 (Master gate, open first & close last)
Insert the stripped cable wires into the appropriate terminals on the opener terminals block. The
red
wire should
be inserted into the
“+MOTOR1”
terminal(#15), the
black
wire into
“MOTOR1-”
terminal (#16), the
blue
wire
into
“ULMT1”
terminal(#17), the
green
wire into
“COM”
terminal(#18), and the
yellow
wire into
“DLMT1”
terminal (#19).
2. Actuator 2 (Slave gate, close first & open last)
The
red
wire should be inserted into the
“+MOTOR2”
terminal(#20), the
black
wire into
“MOTOR1-”
terminal
(#21), the
blue
wire into
“ULMT1”
terminal(#22), the
green
wire into
“COM”
terminal(#23), and the
yellow
wire into
“DLMT1”
terminal (#24).
3. Battery OR AC-DC power supply (Required but not included)
Please connect them refers to the chapter
“Connection of the power supply”
.
4. AC transformer (Only used to charge the batteries)
Insert the stripped cable wires into
AC24V
(#13) terminals to the control board. No matter the polarity. It’s
no need to use it when you choose the AC-DC power supply as the power source.
5. Alarm Lamp (optional)
The red wire of the alarm lamp should be inserted into either
LAMP (#25)
terminal, the white wire into the other
one
(#26)
.
6. Photocell Beam System (PBS) (optional)
Use a 2-core cable to connect the
“+ ~”
terminal of the photocell’s emitter to the “
+24
” (#1) terminal, the
“- ~”
terminal to the “
GND
” (#3) terminal. Also the
“+ ~”
and
“- ~”
terminals of the photocell’s receiver should be
connected to the “
+24
” and “
GND
” terminals in parallel.
Use another 2-core cable to connect the
“NC”
terminal of the receiver to the “
PHOTO
” (#2) terminal, the
“COM”
terminal to the “
GND
” (#3) terminal.
7. Push Button (optional)
The push button should be wired to the “#4 and “#5” terminals. No matter the polarity. The gate operator works
alternately by pressing the button (open-stop-close-stop-open).
8. Electric Lock (optional)
A lock plus board is required to connect the electric lock to the control board. The 2 wires of J1 of lock plus
should be wired to the “9#” and “10#” terminal of the control board. No matter the polarity. Red wire of J2 should
be wired to the 11# terminal and yellow wire of J2 should be wired to the 12# terminal. Red wire of J3 should be
connected to the red wire of electric lock and also the yellow wire of J3 should be connected to the yellow wire
of electric lock.
NOTE: If you use the 24VDC AC-DC power supply as the power source and intend to use the electric
lock, the open delay time of the 2 actuators should be more than 4S.
Cut/remove existing Plug & Play
fitting from motor cable.
Strip wires to expose the
coloured wires.