voltage level. Modify the voltage level in the controller. (Normally open type corresponds to
a level defined the direction of the arrow down, normally closed type corresponds to the
level defined arrow up).
2)
The origin detection switch is broken. Replace a new one.
3)
The origin detection switch connects interface board not well. Refresh the cable to confirm
the wiring is correct.
4)
Too much interference, resulting in the illusion of the detection switch has been
triggered. Recalibrated the whole circuit.
5)
The interface board is broken. Depot Repair.
6)
50-pin data cable is broken. Replace the data cable.
8. Abnormally running when processing or the actual file is different from theoretical file
1)
The system program disorder.
2)
Too much external interference lead the controller cannot work normally. Re-adjust overall
circuit. (The wires of weak current and strong current should be separately binding, the
inverter and other components should be separated connected each GND of themselves).
3)
There is something wrong while converting the file format and the program appears illegal
characters or system unrecognized codes. Recommended to use third party simulation
software to review the program paths.
9. Start automatic tool setting, the tool does not stop after touching C.A.D (Tool sensor).
1)
The cutter signal cable connects X4 maybe broken circuit.
2)
The "GND" signal port on the interface board hasn’t been connected with spindle housing or
poor connection.
3)
Go to “MACHINE SETUP”-“Input Confi” to confirm if X4 is enabled.
10. Coordinate value changes on screen, but the machine does not move
1)
If it is one axis not moving, it maybe wiring problem. Change another normal terminal to this
axis wiring terminal, if it moves properly indicating the rear parts of motor driver have no
problem. Check if there is something wrong with interface board or 50-pin cable. If it is still
not moving, it is necessary to detect the corresponding drive and motor.
2)
If all axes are not moving, firstly, check if there are problems in the 50-pin cable and