Beijing RichAuto S&T Co., Ltd.
23
Distance Time Limit (Unit: s)
When the Distance mode was selected, it will automatically switch back to Continuous
movement mode if there is no action for a certain time of period. To avoid the spindle hits
against the machine body (Under this circumstance, such as the user have set a big Distance
value and forgot to switch back to Continuous mode). The systems default Distance mode limit
time is 30s.
Input Confi (Input Port Configuration)
Enable or disable each input port by the user. You could disable X5-X8 if there is no signal on
these ports by yourself.
Input Configuration
Enable or Disable the input port signals. If X5-X8 have connect signal, could disable X5-X8 signal
under this menu.
4.2.2 Auto Pro Setup
This menu is used to set processing parameters, G code attributes etc.
Menu structure of Auto Pro Setup
Work Speed (Unit: mm/min)
Including work speed and fast speed, system default is 3000 mm/minute.
Safe Height (Unit: mm)
Z axis lifting height during processing. System default is 40.000mm.
Auto Pro Set
Auto Scale
Stop Status
Fall Scale
G Code Setup
Pro Attribute
Array Work
Work Speed
Safe Height