Control Panel Board Connections
The Control Panel provides power and inputs for your Reversing Devices (up to 3), Activation Devices (up to 2), as well as a
wired Push Button Station, and a Remote Radio Receiver. Two on-board relays provide signaling for a variety of programmable
options. Further connections are available for Traffic Signals, a buzzer and flashing Amber signal (while the door is in motion) and
a door lock switch (prevents the door from moving while activated). A receptacle for Richards-Wilcox’s wireless peripheral devices
(impact/tilt sensor, reversing edge, etc.) is also provided.
Reversing Devices
The Dyna-Hoist accepts UL325 Monitored Devices, as well as standard non-monitored Devices. Connect the provided reflective
photo-eye into the terminal labelled ‘1’. Any UL325 'monitored' reversing device should be connected into the terminal labelled
‘2’. Any other added reversing photo-eyes, light curtains and reversing edges should be connected into the terminal labelled ‘3’.
Follow the wiring diagrams included in this manual, and installation instructions provided with your reversing device for further
mounting and connection details. Please note that without a connected, functional reversing device, the Closing Timer and Single
Push auto-closing features of the door are de-activated – Push/Hold to Close protocols will be initiated.
Activation Devices
Automated, wired activation devices, such as Floor Loop Detectors, Pull Cords, Motion Detectors and Photo-Eyes (up to a
maximum of 2 wired devices) used to open the door are connected here. Follow wiring diagram below and refer to the instructions
provided with your activation device for precise connection and mounting details. Note that all devices connected to terminal
A1will open the door to a position just shy of the full opening height, and devices connected to terminal A2 will open the door to
the set limit.
Push Button Station
Connect an added Push Button station to the other side of your door using these inputs. N/O dry contacts are required. Note that
Push Button Stations can be programmed to raise the door to the fully open or set limit position. Refer to the wiring diagram for
further connection details. Push Button Stations are available from RW, please contact us for details.
Remote Radio
Connect your receiver to the provided terminals – as the Dyna-Hoist control panel enclosure is non-metallic, external antenna not
necessarily required. Note that Remote Radio can be programmed to raise the door to the fully open, or set limit position. Refer
to the wiring diagram for further connection details. Remote radio transmitters and receivers are available from Richards-Wilcox,
please contact us for details.
Door Lock
These terminals are available to de-activate door functionality, whether it is a simple switch, or a sensor providing a signal when the
door is locked for the night. Another available option is connecting this to a programmable timer relay to allow door operation for
a pre-determined schedule. Refer to the wiring diagram for further connection details. Contact Richards-Wilcox for information on
their Door Lock Sensor Kit.
Traffic Light
To install an LED stop and go light, use the provided terminals at the bottom of the board. The red connects to the ‘R’ terminal, the
green connects to the ‘G’ terminal and the common should be wired into the ‘+24’ terminal. Ensure that you are using LED traffic
lights (not incandescent) with a maximum consumption of no more than 100mA. The traffic light will stay red when the door is in
motion or the closed position, and will be green in the fully open position only. The red can also be programmed to flash when
the door is in motion, and in advance of close when using the closing timer (See Page 22 for futher details). The ‘Y’ terminal is for
a secondary flashing Amber LED beacon and/or audible signal to indicate when the door is in motion. While accessing the Setup
Menu, the traffic lights will turn off, and the Amber beacon, if installed, will flash. LED Stop and Go Lights from Richards-Wilcox
are highly recommended, please contact us for details. Refer to the wiring diagram for further connection details. Note: DO NOT
USE INCANDESCENT SIGNALS WITH THIS OPERATOR. LED LIGHTS ONLY.
Output Relay Connections
NO and NC relay output connections are provided for interlocking with other material handling equipment (i.e. dock leveller) or
security/fire systems. These outputs can be programmed (see Output Relay Setup) to energize when the door is at the Open or
Closed Limit. Refer to the wiring diagram for further instructions.