MOTION DETECT TIME
As an added safety feature, the encoder monitors the rotation of the shaft. Should it detect
no motion where there should be motion, the system will halt the cycle command, and show a
fault display of 'NO MOTION DETECTED'. The allowable delay before this fault is recognized
by the system can be adjusted from 0.2s to 0.6s, but should not be altered from the Factory
Default setting of 0.3s unless instructed to do so by technical support personnel.
FACTORY RESET
This setting allows for a reset of all menu options to the factory default. These are the Factory
Settings:
QUICKSTART MENU
Closing Timer: ...................................................... OFF
Voltage Range: ................................................... 208V-240V
Motor Position: ................................................... Left
Door Limits Setup: ............................................. 4 Rotations - Must be Re-Programmed by Installer
Open Speed: ...................................................... 3
Close Speed: ...................................................... 3
ADVANCED SETUP MENU
Reversing Timer:.................................................. 1.0 Seconds
PWM Frequency: ............................................... 12 kHz
Dynamic Brake: .................................................. OFF
Opening Force: ................................................... 10
Closing Force: .................................................... 2
Open Slow Speed: ............................................. Normal
Close Slow Speed: ............................................ Normal
Close Rampdown: .............................................. Auto
Open Rampdown: ............................................. Auto
Open Limit Options - Push Button: ................ Set Limit
Open Limit Options - Remote Radio: ............ Set Limit
Output Relay: ....................................................... Energized When Open
Red Flashing: ....................................................... OFF
Advanced Red: .................................................... OFF
Maintenance Schedule: ..................................... 250,000 Cycles
Open Limit Switch: ............................................. No
Close Ramp-Up Time ........................................ 1.0 Seconds
Motion Detect Time ............................................ 0.3 Seconds
After performing factory reset (if deemed necessary), adjust settings as required, and re-program limit settings and perform calibration
thereafter.
EXITING ADVANCED MENU - CALIBRATION & TESTING
To exit from the ADVANCED MENU, press and release the STOP button while ADVANCED MENU appears on the LCD. This will
bring you back to the QUICKSTART MENU. Press and release the STOP button again to exit all menus and to test the settings that
you have changed. If, while you were in the ADVANCED MENU and have saved changes to the PWM Frequency, Open Rampdown or
Close Rampdown you will be required to do a quick system calibration. Screen prompts will provide real-time instruction on calibration
requirements. See Page 21 for more detailed informaiton on Calibration.
Once Calibration is completed or if it was not required, the system will run a quick diagnostic, and the LCD will read 'DOOR IS READY,
PRESS OPEN TO BEGIN'. This is a prompt to open the door and reset the encoder, and also appears whenever there is a power
reset. Once the door is opened (press the OPEN button, door will rise at slow speed until it rests against Limit Brackets), normal door
function of the operator will resume. It is now that testing of any of the changed settings can commence.