Control Panel Mounting
The control panel should be securely mounted at or around
eye level (minimum 5 ft. from floor) on the same side as
the operator/junction box. Ensure that the control panel is
mounted far enough away from the door as to avoid user
contact with the door while in operation, but close enough
that the user has clear view of the door at all times. Four (4)
control mounting brackets are provided to facilitate mounting.
See Fig: 8
Photo-Eye or Thru-Beam Sensor Mounting
The included reflective photo-eye or thru-beam sensor should
be mounted so that it scans area that spans the entire width
of the door at a height of no more than 6 inches from the
ground. The sensor (reflective photo-eye) or receiver (thru-
beam) should be mounted on the operator side (as it will be
wired into the control panel), while the reflector or transmitter
should be mounted on the opposite side of the door, facing
the sensor/receiver so that its center meets the beam. Use
the included mounting bracket(s) to secure to either the
door tracks or the wall. Refer to the specific mounting details
provided with the sensor. For final alignment of the sensor,
put unit in STARTUP MENU (see page 18) to apply power
to the sensor (after WIRING – see page 13 for additional
wiring diagram). Once properly aligned in STARTUP MENU,
the indicator will light up in confirmation. Note that upon exit
from the STARTUP MENU, the sensor will only become active
when the door is closing.
See Fig: 9 for mounting reference.