4.4.2 Setup – Format Menu
4.4.2.1 Primary and Secondary Menus
Figure 4-6. Format – Primary and Secondary Menus
4.4.3 Setup – Calibration Menu
Figure 4-7. Setup – Calibration Menu
Parameter
Description
format
Format – Sets the decimal point and the display divisions for the Primary (
primar
) and Secondary (
secndr
)
display weight format; For example, select
8888.885
if a count by of 0.005 is needed or select
888820
if a count by
of 20 is needed (the
8
s serve as placeholders and show a breakdown of how digits will display);
Settings:
888881
(Primary default), 888882, 888885, 888810, 888820, 888850, 888100, 888200, 888500, 8.88881,
8.88882, 8.88885, 88.8881, 88.8882, 88.8885, 888.881, 888.882, 888.885, 8888.81, 8888.82, 8888.85, 88888.1,
88888.2, 88888.5 (Secondary default)
Units
Units – Sets the units type;
Settings:
LB
(Primary default), KG (Secondary default), OZ, TN, T, G, NONE
Enable
Enable – Enables the front panel UNITS button to toggle between the primary and secondary formats (only displays
under Secondary);
Settings:
ON
(default), OFF
Table 4-5. Format – Primary and Secondary Menu Parameters
Parameter
Description
wzero
Zero Calibration – Executes the zero calibration process; See
zrocnt
Zero Calibration Count – Displays the raw count value at the zero weight; A zero calibration (WZERO)
generates this raw count value; Manually changing this count value changes the zero weight and negates the
zero calibration
wval
Test Weight Value – Sets the weight value for the span calibration; See
;
Enter value: 0.00001–99999.99999,
10000.0
(default)
wspan
Span Calibration – Executes the span calibration process; See
spncnt
Span Calibration Count – Displays the raw count value at the span weight; A span calibration (WSPAN)
generates this raw count value; Manually changing this count value changes the span weight and negates the
span calibration
Table 4-6. Setup – Calibration Menu Parameter
Setup
Format
FORMAT
UNITS
PRIMAR
FORMAT
UNITS
ENABLE
SECNDR
Setup
Calibr
zrocnt
WZERO
WVAL
spncnt
WSPAN
Point1-4
WLIN
REZERO
Wlinv1-4
wlinc1-4
wlinf1-4
lstzro
tmpzro