![Rice Lake Synergy 680HE Technical Manual Download Page 44](http://html1.mh-extra.com/html/rice-lake/synergy-680he/synergy-680he_technical-manual_1453958044.webp)
680HE Synergy Indicator
38
Visit our website
4.4.9 Setup – Digital I/O Menu
Figure 4-21. Setup – Digital I/O Menu
4.4.10 Setup – Analog Output Menu
Instructions to install and setup the analog output option card are provided with the option card kit (PN 195084).
Figure 4-22. Setup – Analog Output Menu
Parameter
Description
bit 1-4
Digital I/O Bit 1-4 – Specifies the mode and function of the digital I/O pins;
Settings:
OFF
(default), PRINT, ZERO,
TARE, UNITS, PRIM, SEC, CLEAR, DSPACC, DSPTAR, CLRACC, CLRTAR, NT/GRS, GROSS, NET, CLRCN,
KBDLOC, BATRUN, BATSTR, BATPAS, BATRST, BATSTP, OUTPUT
Table 4-18. Setup – Digital I/O Menu Parameters
Parameter
Description
source
Source – Specifies the scale tracked by the analog output;
Settings:
GROSS
(default), NET
output
Output – Specifies the voltage or current tracked by the analog output;
Settings:
0-10V
(default), 0-20MA, 4-20MA
erract
Error Action – Specifies how the analog output responds to system error conditions;
Settings:
FULLSC
(default)
– Set to full scale (10 V or 20 mA)
HOLD
– Holds current value
ZEROSC
– Sets to zero value (0 V, 0 mA or 4 mA)
min
Minimum Weight – Specifies the minimum weight value tracked by the analog output;
Enter value: ±99999.0,
0.0
(default)
max
Maximum Weight – Specifies the maximum weight value tracked by the analog output;
Enter value: ±99999.0,
10000.0
(default)
twzero
Tweak Zero – Adjusts the offset of the analog output zero value;
Enter value: 0–65535,
0
(default)
twspan
Tweak Span – Adjusts the offset of the analog output span value;
Enter value: 0–65535,
59515
(default)
Table 4-19. Setup – Analog Output Menu Parameters
Setup
DIGIO
bit 3
bit 4
bit 1
bit 2
slot 0
Setup
ALGOUT
OUTPUT
ERRACT
MIN
MAX
SOURCE
twzero
twspan
Summary of Contents for Synergy 680HE