Configuration
© Rice Lake Weighing Systems
●
All Rights Reserved
37
start
Starting Setpoint – Specifies starting setpoint number; do not specify number of the TIMER or CONCUR setpoint itself; TIMER or
CONCUR setpoint begins when starting setpoint begins;
Enter value: 1–8,
1
(default)
end
Ending Setpoint – Specifies ending setpoint number; do not specify number of the TIMER or CONCUR setpoint itself; TIMER or CONCUR
setpoint stops when ending setpoint begins;
Enter value: 1–8,
1
(default)
time
Time – For TOD setpoints, specifies the time at which the setpoint becomes active; the format used to enter the time (12hour or 24hour)
is based on the value specified for the TIMFMT parameter in the Program menu (HHMM);
Enter value:
0000
(default)
duraton
Duration – For TOD setpoints; specifies the length of time the digital output associated with this setpoint changes state; value is entered in
hours, minutes, and seconds (HHMMSS);
Enter value:
000000
(default)
preval
Preact Value – Specifies the preact value for setpoints with PREACT set to ON or LEARN; depending on the TRIP setting specified for the
setpoint, the setpoint trip value is adjusted up or down by the PREVAL value;
Enter value: 0.0–99999.0,
0.0
(default)
preadj
Preact Adjustment – Setpoints with PREACT set to LEARN, specifies a decimal representation of the percentage of error correction
applied (50.0 = 50%, 100.0 = 100%) each time a PREACT adjustment is made;
Enter value: 0.0–100.0,
50.0
(default)
presta
Preact Stabilization Time-Out – Setpoints with PREACT set to LEARN, specifies the time, in 0.1-sec intervals, to wait for standstill before
adjusting the PREACT value; setting this parameter to a value greater than zero disables the learn process if standstill is not achieved in
the specified interval (in tenths of a second);
Enter value: 0–65535,
0
(default)
pcount
Preact Learn Interval Count – Setpoints with PREACT set to LEARN, specifies the number of batches after which the preact value is
recalculated; the default value, 1, recalculates the preact value after every batch cycle;
Enter value: 1–65535,
1
(default)
relnum
Relative Number – For relative setpoints, specifies the number of the relative setpoint;
Enter value: 1–8,
1
(default)
Target weight for this setpoint is determined as follows:
POSREL setpoints, the value of the relative setpoint plus the value (VALUE parameter) of the POSREL setpoint
NEGREL setpoints, the value of the relative setpoint minus the value of the NEGREL setpoint
PCTREL setpoints, the percentage (specified on VALUE parameter of the PCTREL setpoint) of the target value of the relative
setpoint
alarm
Alarm – Specify ON to display the word ALARM on the primary display while the setpoint is active (batch setpoints) or while the setpoint is
not tripped (continuous setpoints);
Settings:
OFF
(default), ON
clracM
Clear Accumulator – Specify ON to clear the accumulator when the setpoint is satisfied;
Settings:
OFF
(default), ON
clrtar
Clear Tare – Specify ON to clear the tare when the setpoint is satisfied;
Settings:
OFF
(default), ON
pshacM
Push Accumulator – Specify ON to update the accumulator and perform a print operation when the setpoint is satisfied; specify ONQUIET
to update the accumulator without printing;
Settings:
OFF
(default), ON, ONQUIET
pshprt
Push Print – Specify ON to perform a print operation when the setpoint is satisfied; specify WAITSS to wait for standstill after setpoint is
satisfied before printing;
Settings:
OFF
(default), ON, WAITSS
pshtar
Push Tare – Specify ON to perform an acquire tare operation when the setpoint is satisfied;
Settings:
OFF
(default), ON
NOTE: PSHTAR acquires the tare regardless of the value specified for the REGULA parameter in the Program menu
dslot
Digital Output Slot – Lists all available digital I/O slots; this parameter specifies the slot number of the digital I/O card referenced by the
DIGOUT parameter;
Settings:
NONE
(default), 0
digout
Digital Output – Lists all digital output bit numbers available for the specified digital output slot; this parameter is used to specify the digital
output bit associated with this setpoint; use the DIGIO menu to assign bit function to OUTPUT;
Enter value: 1–4,
1
(default)
NOTE: For continuous setpoints, the digital output becomes active (low) when the condition is met; for batch setpoints, the digital output is
active until the setpoint condition is met
sense
Sense – Specifies whether the value of the digital output associated with this setpoint is inverted when the setpoint is satisfied;
Settings:
NORMAL
(default), INVERT
batch
Batch – Specifies whether the setpoint is used as a batch (ON) or continuous (OFF) setpoint;
Settings:
OFF
(default), ON
branch
Branch Destination – Specifies the setpoint number to which the batch sequence is to branch, if the current setpoint is not satisfied upon
initial evaluation (0 = do not branch);
Enter value: 0–8,
0
(default)
enable
Enable – Specifies if setpoint parameters display in user mode;
Settings:
ON
(default), OFF
access
Access – Specifies the access allowed to setpoint parameters in user mode;
Settings:
ON
(default) – Values can be displayed and changed
HIDE – Values cannot be displayed or changed
OFF – Values can be displayed but not changed
alias
Alias – Name for the setpoint;
Enter characters: Alphanumeric entry up to 8 characters,
SETPT
(default)
Parameter
Description
Table 4-17. Kind Parameter Descriptions (Continued)