Hybrid AC Driver [RMCS-1120]
2-phase, 4-lead Motors Connections
4 lead motors are the least flexible but easiest to wire. Speed and torque will depend on winding
inductance. In setting the drive output current, multiply the specified phase current by 1.4 to determine
the peak output current.