![Retigo Blue Vision Series Operating Manual Download Page 50](http://html.mh-extra.com/html/retigo/blue-vision-series/blue-vision-series_operating-manual_1445796050.webp)
50
Err 40
Outage of the chamber
thermal fuse, boiler (boiler
combi ovens only), draught
interrupter (only gas combi
ovens with a draught
interrupter) or switchboard
thermal fuse.
Contact an authorised
service company.
Err 41
Cooling error - overheating
of electronics.
Clean the dust filter.
If the error occurs
repeatedly, please contact
an authorised service
company.
Err 42
Overheating of the boiler
heating element.
The combi oven will
automatically switch to the
reserve injection state and
it is possible to continue
using it. After the combi
oven is turned off and then
on again, it will try to start
up the boiler. If the problem
reoccurs, please contact
an authorised service
company.
Err
60-79
Modbus communications
error.
Disconnect the power
supply to the combi oven
(not "Standby" mode), wait
30 seconds and then turn
on the combi oven again
(reconnect the power
supply). If the problem
reoccurs, please contact
an authorised service
company.
Err
80-91
Frequency converter error.
If the problem reoccurs,
please contact an
authorised service
company.
Err 95
Incorrect blower speed.
Err 96
Lighting up error.
Check that the gas supply
is open and try to start
cooking again. If the
problem reoccurs, please
contact an authorised
service company.
Err 100
System error
Contact an authorised
service company.
•
Only an authorized service trained and certified by the manufacturer is
allowed to repair defects in the appliance. Unprofessional intervention
by an unauthorized service voids the warranty!
•
For the entire observation time, the combi oven must be subjected
to regular inspections, tests and reviews according to the applicable
regulations in the owner’s country.
User manual | Blue Vision Combi Ovens I
10 ERROR MESSAGE TABLE