10 I TABLE OF ERROR MES-
SAGES
When you work with the appliance, the display may show error messages.
Their meanings are as follows:
Err 18
When draining the boiler, the
water level did not fall below
the maximum water level
within the set time limit.
The combi oven will
automatically switch to the
reserve injection state and
it is possible to continue
using it temporarily. After
the combi oven is turned
off and then on again, it will
try to start up the boiler.
If the problem reoccurs,
please contact an authorised
service company.
Err 26
Flap valve error. The
automatic flap valve is not
working correctly.
Incorrect function of the flap
valve may affect cooking
results, however, it is possible
to continue using the combi
oven temporarily. Contact an
authorised service company.
Err 31
Drain heat sensor error.
The combi oven can
temporarily be used in
all modes. Contact an
authorised service company.
Err 33
Boiler heat sensor error.
The combi oven will
automatically switch to the
reserve injection state and
it is possible to continue
using it temporarily. After
the combi oven is turned
off and then on again, it will
try to start up the boiler.
If the problem reoccurs,
please contact an authorised
service company.
Err 34
Error of the 1-point
temperature probe.
The combi oven can
temporarily be used
in all modes with the
exception of the modes
with a temperature probe.
Contact an authorised
service company.
Err 35
Chamber heat sensor error.
Error blocks work in
all modes. Contact an
authorised service company.
Err 36
Error of the 6-point
temperature probe.
The combi oven can
temporarily be used
in all modes with the
exception of the modes
with a temperature probe.
Contact an authorised
service company.
Err 37
Thermistor disconnected.
Contact an authorised
service company.
Err 38
Thermistor short-circuited.
ERROR
DESCRIPTION
SOLUTION
Err 10
The minimum water level
was not reached in the boiler
within the set time limit
despite the maximum water
level being reached.
The combi oven will
automatically switch to the
reserve injection state and
it is possible to continue
using it temporarily. After
the combi oven is turned
off and then on again, it will
try to start up the boiler.
If the problem reoccurs,
please contact an authorised
service company.
Err 11
Chamber heating element
error.
The combi oven cannot
continue operating. Contact
an authorised service
company.
Err 12
The maximum water level
was not reached in the boiler
within the set time limit.
The combi oven will
automatically switch to the
reserve injection state and
it is possible to continue
using it temporarily. After
the combi oven is turned
off and then on again, it will
try to start up the boiler.
If the problem reoccurs,
please contact an authorised
service company.
Err 13
The minimum water level
was not reached in the boiler
within the set time limit.
Check the water supply inlet
(open tap). The combi oven
can be used temporarily
only in hot air mode. If
the problem reoccurs,
even when water supply is
provided, please contact an
authorised service company.
Err 15
Failure of motor heat
protection. Signals motor
overheating above the set
limit.
Contact an authorised
service company.
Err 16
The boiler was not
preheated within the set
time limit.
The combi oven will
automatically switch to the
reserve injection state and
it is possible to continue
using it temporarily. After
the combi oven is turned
off and then on again, it will
try to start up the boiler.
If the problem reoccurs,
please contact an authorised
service company.
Err 17
When draining the boiler, the
water level did not fall below
the minimum water level
within the set time limit.
User manual | Blue Vision Combi Ovens I
10 ERROR MESSAGE TABLE