![Retigo Blue Vision Series Operating Manual Download Page 31](http://html.mh-extra.com/html/retigo/blue-vision-series/blue-vision-series_operating-manual_1445796031.webp)
31
User manual | Blue Vision Combi Ovens |
05 EXTRAS
|
5.2 DRAWER TIMING
5.2 DRAWER TIMING
For individual drawers that you prepare in the same cooking mode (steam,
hot air or combination), the drawer timing function allows you to assign
different processing times or different final temperatures for the centre of
the food.
With rack timing, it is also possible to create timing programs (
4.2/4.2.7),
which you may save to the program directory and call up at any time without
any further settings. You merely define the specific times for the individual
racks.
5.2.1 Cooking in Drawer Timing mode – Manual settings
1
ENTER EXTRAS
2
PRESS
3
SELECT MANUAL SETTINGS
4
SELECT A COOKING MODE
5
BASED ON THE SELECTED COOKING MODE, SELECT:
5.1
Humidity level (
4/4.1, point B2
) for combo mode
5.2
Flap valve opening level (
4/4.1, point B3
) in the case of the Hot air
mode
6
SELECT A DEFAULT TEMPERATURE FOR THE COOKING CHAMBER
7
SELECT A DEFAULT SETTING FOR THE FAN
(
4/4.1, point B6
)
8
PRESS
9
SET THE TIME OR TEMPERATURE ON THE NEEDLE
9.1
OPTION: TIME SETTING
Set the time in the clock order: Minutes: Seconds after which the timer
stops
Press
Enter the name of the timer
Press
9.1.1
OPTION: ADDING ANOTHER TIMER
To add another timer, repeat the procedure from point 8-9