Owners Manual
41
INSTALLATION
PRE INSTALL TEST
It’s always a good idea to test the column array as a complete unit before it is installed to make sure
all the connections were properly made and all the transducers are working. If there is a problem, its
a lot easier to find and correct before the unit is physically installed.
Use one of the 3-pin connectors supplied with the assemby to connect audio to the loudspeaker and
the power cord to connect the power. You do not need the digital control cable to conduct a simple
audio test.
Notice that these connections can be made inside any one of the access chambers. This Iconyx fea-
ture gives you a choice of where the audio, power and digital control connections are made. You
can, for example, bring the power into the bottom module and the audio and digital control lines into
the top module.
CABLING REQUIRED
POWER
Your Iconyx column was supplied with a 6-foot AC Power cord with IEC connectors
.
Note that the column(s) do not include a power on/off switch and you will have to make sure
an external power on/off switch is provided. Each module, however, does include a self-
restoring circuit breaker as protection against damage in the event of an internal failure.
Power requirements for Iconyx columns are listed below.
IC8 and IC16-8:
Universal 100/240 VAC, 50/60 Hz; 120 Watts
IC16 and IC32-16:
Universal 100/240 VAC, 50/60 Hz; 240 Watts
IC24:
Universal 100/240 VAC, 50/60 Hz; 360 Watts
IC32:
Universal 100/240 VAC, 50/60 Hz; 480 Watts
WARNING:
1. The AC mains must be connected to a mains socket outlet with a protective earthing
connection.
2. To remove power from the Iconyx column, disconnect the AC power cord.
3. If the knockout on the rear cover is used during installation, a means of preventing
damage to the AC power cord must be provided.
AUDIO & DIGITAL CONTROL LINES
A block diagram of a simple four column system follows. Note that the RS422 digital control cable
and the audio signal cable loop from column to column.
RS422 Contol Cable
Audio Cable
From Audio Source